My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0080902 SSCRPT
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KASSON
>
31411
>
2600 - Land Use Program
>
SR0080902 SSCRPT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2019 3:48:46 PM
Creation date
11/8/2019 3:30:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSCRPT
RECORD_ID
SR0080902
PE
2603
STREET_NUMBER
31411
Direction
S
STREET_NAME
KASSON
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
25534001
ENTERED_DATE
7/17/2019 12:00:00 AM
SITE_LOCATION
31411 S KASSON RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Show location of smoke detector, <br /> 8. ELECTRICAL 120V permanently wired, with <br /> 8.1 Show location of all electrical battery backup UBC Section <br /> receptacles,switches and fixtures. 310.9.1: <br /> 8.2 Electrical receptacle locations In each sleeping room. � �� <br /> and/or spacing is not adequate in: Centrally located corrid r giving <br /> access to bedrooms. <br /> c. In each story and basement. <br /> d. In multi-story,in close proximity <br /> 8.3 In kitchens and dining areas of to upper landing of stairway. <br /> dwelling units a receptacle outlet e. Where the ceiling height of a room <br /> shall be installed at each counter opens into the hallway serving the <br /> space so that no point along the bedrooms exceeds that of the <br /> wall line Is more than 24 inches, hallway by 24 inches or more, <br /> measured horizontally from a smoke detectors shall be installed <br /> receptacle outlet in that space. in both areas. <br /> Island and peninsular counter tops <br /> 12 inches or wider shall Note on plans that all smoke <br /> have at least one receptacle. NEC detectors shall be audible in all <br /> Section 210-52(c). sleeping areas of the dwelling unit. <br /> UBC Section 310.9.1.4. <br /> 8.4 Receptacle outlet shall be installed <br /> in hallways 10 feet or more in 8.8 Note in the following locations that <br /> length. convenience outlets shall be GFCI <br /> Protected: bathrooms, all kitchen <br /> 8.5 Electrical receptacles in habitable counter top receptacles, within six <br /> rooms shall be spaced a maximum feet of wet bar sinks, outdoors, <br /> of 12 feet apart, 6 feet maximum garages, grade-level portions of <br /> from any door opening, any wall unfinished accessory buildings <br /> space wider than 24 inches. used for storage or work areas and <br /> unfinished basements. NEC,Sction <br /> 210-8. <br /> it <br /> 17 <br />
The URL can be used to link to this page
Your browser does not support the video tag.