EoMuwn G BRAWN JP <br /> I�_• UUV[MNaN <br /> • .p.ti <br /> c..i r o w i• MAtrmtw RaouNiauu <br /> Water Boards <br /> Central Valley Regional Water Quality Control Board <br /> 14 June 2013 <br /> Mr. Phil Goalwin <br /> E2C Remediation <br /> 5300 Woodmere Drive, Suite 105 <br /> Bakersfield, CA 93313 <br /> COMMENTS ON HIGH VACUUM EXTRACTION REPORT AND SITE DECOMMISSIONING <br /> WORK PLAN— FORMER BUSY BEE CLEANERS, LODI, SAN JOAQUIN COUNTY <br /> Central Valley Regional Water Quality Control Board (Central Valley Water Board) staff has <br /> reviewed the reports titled "High-Vacuum Extraction Report of Findings"(Report) and "Site <br /> Decommissioning Work Plan" (Work Plan) dated 10 April and 11 April 2013, respectively, <br /> prepared by E2C Remediation. Staff from the Central Valley Water Board, City of Lodi, and E2C <br /> met on 24 October 2012 to discuss the status of the groundwater cleanup and future activities at <br /> the site. <br /> High Vacuum Report of Findings <br /> The Report described batch pumping operations that occurred between December 2012 and <br /> February 2013 in accordance with the batch pumping plan which was approved by Central <br /> Valley Water Board staff in November 2012. Approximately 11,000 gallons of groundwater was <br /> extracted from wells EX-1BB and MW-7BB. Initial concentrations of tetrachloroethylene (PCE) <br /> in EX-1 BB were 23.3 pg/L and 30.7 pg/L in MW-7BB. After batch pumping, concentrations of <br /> PCE decreased to 10.2 pg/L in EX-1 BB and 10.3 in MW-7BB. The batch pumping operations <br /> removed approximately 2.63 pounds of PCE. <br /> Site Decommissioning Work Plan <br /> The Work Plan described activities associated with abandoning the groundwater remediation <br /> system. The system consists of the following components: one 6-inch extraction well, 22 <br /> groundwater monitoring wells, 38 air sparge wells, and 29 vapor extraction wells. E2C proposes <br /> to over-drill the top 3 feet of each well and pressure grout the remainder, per San Joaquin <br /> County Environmental Health Department and City of Lodi permit specifications. The piping will <br /> be left in place under asphalt paving in the City's right-of-way. The ends of the piping will be <br /> capped with concrete plugs. Manifold piping at each equipment compound will be cut flush with <br /> ground surface and each pipe will be capped with a concrete plug. <br /> Comments <br /> Central Valley Water Board staff concurs with the Report finding that data show the batch <br /> pumping operations achieved the objectives set forth in our October 2012 meeting. No <br /> KAft E. LONSLEY ScD. P.E.,cHAm I PAMELA C.CIIEEDOH P.E.. BCEE.EMOUTIVE OFFICER <br /> 11020 Sun Canter Drive 1200,Rancho Cordova.CA 95670 1 www.wat*rboarde.ca.gov/centrolvaney <br /> ♦&R.craSo PAV{P <br />