Laserfiche WebLink
Project F114.01 9 November 1991 <br /> SYSTEM MONITORING SUMMARY <br /> EVAX TECHNOLOGIES, INC. <br /> Site: Exxon Station RS #7-1050 System Start Up: 3/8/91 <br /> 909 West Hammer Lane <br /> Sto^kton, California <br /> i <br /> System Incinerator Incinerator Incinerator <br /> Test Date 10/30/91 10/17/91 9/12/91 <br /> EXTRACTION TVH VP TVH VP TVH VP <br /> POINT <br /> VP-1 ND 0 190 0 ND C <br /> VP-2 ND 0 110 0 100 0 <br /> VP-3 ND C 8 C 50 C <br /> VP-4 NO C 26 C 110 0 <br /> VP-5 ND 0 160 0 90 0 <br /> VP-6 NO C 300 0 50 C <br /> MW-3 NO 0 220 0 280 0 <br /> MW-4 NO 0 100 0 150 0 <br /> Detection <br /> Limit (ppm) 1.0 1.0 1.0 <br /> Method TLV TLV TLV <br /> EXTRACTION POINT - Extraction probe/well identification as indicated on <br /> site plan. <br /> TVH - Total volatile hydrocarbons in parts per million (ppm) on a <br /> volume/volume basis. <br /> TLV - Threshold Limit Values meter detects combustible gases by <br /> oxidation using a hexane standard. <br /> VP - Manifold valve position. (0=Open) (C-Closed) <br /> NT - Not tested. <br /> NO •- Below the detection limit. <br /> E <br /> _ 2 _ <br />