Laserfiche WebLink
Project F114.01 • 7 January 1992 <br /> SYSTEM MONITORING SUMMARY <br /> EVAX TECHNOLOGIES, INC. <br /> Site• Exxon Station RS #7-1050 System Start Up: 3/8/91 <br /> 909 West dammer Lane <br /> Stockton, California <br /> i <br /> System Incinerator Incinerator Incinerator <br /> Test Bate 12/27/91 12/11/91 10/30/91 <br /> EXTRACTION TVH VP TVH VP TVH VP <br /> POINT <br /> VP-1 1 0 15 0 NO 0 <br /> VP-2 1 0 10 0 ND 0 <br /> VP-3 ND C 5 C ND C <br /> VP-4 NO C 5 C NO C <br /> VP-5 0.2 0 10 0 ND 0 <br /> VP-6 42 0 80 0 ND C <br /> MW-3 NO C 2 C ND 0 <br /> . MW-4 3200 125 0 ND 0 <br /> Detection -- -- -- <br /> Limit (Ppm) 1.0 1.0 1.0 <br /> Method FID FID TLV <br /> EXTRACTION POINT - Extraction probe/well identification as indicated on <br /> site plan. <br /> TVH - Total volatile hydrocarbons in parts per million (ppm) on a <br /> volume/volume basis. <br /> TLV - Threshold Limit Values meter detects combustible gases by <br /> oxidation using a hexane standard. <br /> VP - Manifold valve position. (O=Open) (C=Closed) <br /> NT - Not tested. <br /> NO - Below the detection limit. <br /> • <br /> - 2 - <br />