Laserfiche WebLink
�! Project F114.01 5 April 1992 <br /> �i SYSTEM MONITORING SUMMARY <br /> EVAX TECHNOLOGIES, INC. <br /> Site: Exxon Station RS #7-1050 System Start Up: 3/8/91 <br /> 909 West Hammer Lane <br /> �! Stockton, California <br /> System Incinerator Incinerator Incinerator <br /> Test Date 3/24/92 3/9/92 2/28/92 <br /> EXTRACTION TVH VP TVH VP TVH VP <br /> POINT <br /> VP-1 2 0 30 0 120 0 <br /> VP-2 NO 0 ND 0 ND 0 <br /> VP-3 NO 0 ND 0 NO 0 <br /> VP-4 ND 0 65 0 25 0 <br /> VP-5 NO 0 NO 0 NO 0 <br /> VP-6 2 0 60 0 100 0 <br /> 'F MW-3 350 0 155 0 280 0 <br /> l MW-4 NO 0 ND 0 ND 0 <br /> Detection ---- --- --- <br /> Limit (ppm) 1 .0 1.0 1 .0 <br /> Method OVA OVA TLV <br />' EXTRACTION POINT - Extraction probe/well identification as indicated on <br /> site plan. <br /> TVH - Total volatile hydrocarbons in parts per million (ppm) on a <br />' volume/volume basis. <br /> TLV - Threshold Limit Values meter detects combustible gases by <br /> oxidation using a hexane standard. <br /> C , VP - Manifold valve position. (O=Open) (C=Closed) <br /> NT - Not tested. <br /> ND - Below the detection limit. <br /> OVA - Organic Vapor Analyzer <br />' FID - Flame Ionization Detector <br /> r <br /> j � v <br /> - <br />