Laserfiche WebLink
CONCLUSIONS AND RECOMMENDATIONS <br /> In summary, the soil conditions examined near the proposed septic system drain field <br /> were found to be suitable for a standard septic system. A satisfactory soil percolation <br /> rate of 5.43 min/in was observed in the shallow soil zone at the test location. <br /> The depth of ground water based on recent aquifer levels is approximately 110 to 132 <br /> feet below ground surface. The ground-water flow beneath the Site is to the north or <br /> northwest at a rate of approximately 18 to 20 feet per mile. Depth-to-water data were <br /> not available for the vicinity of the Site during the 1983 and 1999 high-water seasons. <br /> Because the percolation rate encountered falls between 5.0 and 30.0 min/in, the San <br /> Joaquin County Environmental Health Department will require an eight-foot separation <br /> from the bottom of the dispersal system to ground water. Based on the anticipated <br /> depth to water beneath the Site, this requirement should not present a difficulty. <br /> A water sample was collected from the domestic well on the Site as part of this <br /> investigation. Nitrate was detected in the sample at a concentration of 3.7 mg/L-N, well <br /> below the MCL of 10 mg/L-N. DBCP was not detected in the sample; the MCL for <br /> DBCP is 0.2 ug/L. <br /> Based on a review of San Joaquin County Environmental Health Department map of <br /> nitrate detections in nearby wells, it appears that four wells within a half-mile radius of <br /> the subject Site have been tested for nitrate; it was detected in three at concentrations <br /> greater than 10.0 mg/L-N, and in the fourth at a concentration between 5.1 and 10.0 <br /> mg/L-N. According to the DBCP map, two wells within one-half mile of the Site were <br /> tested for DBCP; no DBCP was detected in either well. <br /> Much of the nearby land to the southeast is agricultural; elevated nitrate levels in the <br /> area likely derive from fertilizer application on these properties. <br /> Based on the method and assumptions described, the nitrate loading calculation <br /> indicates that the use of on-site septic tanks and drain field systems on the Site have <br /> the potential to cause a buildup of nitrate in the aquifer of 17.9 mg/L-N, above the US <br /> EPA drinking water recommendation of 10 mg/L-N. However, based on the <br /> conservative nature of the calculation, depth to water beneath the Site, and clay soil <br /> present (as evidenced by the well drilling log for the domestic well), it is the professional <br /> opinion of Live Oak that septic effluent from the subject Site is unlikely to contribute <br /> significantly to a build-up of nitrate in the ground water. Use of a standard septic <br /> system should be permitted for the new home. <br /> LOGE 1922 Page 14 <br />