My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
440
>
2200 - Hazardous Waste Program
>
PR0521299
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/18/2022 11:36:22 AM
Creation date
11/18/2019 4:28:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0521299
PE
2220
FACILITY_ID
FA0002321
FACILITY_NAME
Delta arco
STREET_NUMBER
440
Direction
W
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
16503003
CURRENT_STATUS
01
SITE_LOCATION
440 W DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Teleph ne: (209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Delta arco 1440 W DR MARTIN LUTHER KING JR BLVD October 03 2018 <br /> Labeling and Storage <br /> 611 HSC 25200.3.1(b) Failure of laboratory to comply with hazardous waste accumulation area requirements o V ❑R ❑COS <br /> Universal Waste <br /> 701 CCR 66273.32(a) UW hand er failed to notify EPA RA and obtain an EPA ID#prior to accumulating>5000kg of UW D V D R D COS <br /> 702 CCR 66273.32(c) Electronic device and CRT handler failed to notify DTSC 30 days prior to accepting offsite UW D V o R D COS <br /> 703 CCR 66273.33(a) UW hand er failed to store UW batteries in a manner that prevents release to the environment D V D R D COS <br /> 704 CCR 66273.33(b) UW hander failed to properly manage universal waste lamps D V D R D COS <br /> 705 CCR 66273.33(c) UW hand er failed to properly manage mercury containing universal waste D V D R D COS <br /> 706 CCR 66273.33.5 UW hand er failed to prevent release of universal waste electronic devices,CRTs or CRT glass D V D R D COS <br /> 707 HSC 25201.16(e) Failed to nanage aerosol cans in a manner that prevents the unauthorized release of waste D V D R D COS <br /> 708 HSC 25201.16(f) Failed to roperly manage containers of waste aerosol cans D V D R D COS <br /> 709 HSC 25201.16(g) Failed to tore used aerosol cans in an accumulation container D V D R o COS <br /> 710 HSC 25201.16(h)(4) No written operating procedure for aerosol can processing D V D R D COS <br /> 711 HSC 25201.160) Failed to submit or amend notification for aerosol can processing D V D R D COS <br /> 712 CCR 66273.34 UW handler(UWH)failed to label universal waste to identify type of universal waste D V D R D COS <br /> 713 CCR 66273.35 UWH sto ed UW onsite greater than one year or was unable to demonstrate storage time D V D R D COS <br /> 714 CCR 66273.36 UWH failed to train employees and maintain records on UW handling and emergency procedures D V D R D COS <br /> 715 CCR 66273.39 UWH failed to keep complete records of each shipment of universal waste for three years D V D R D COS <br /> 716 CCR 66273.40(a)(3)(4) UW handler sending devices/CRTs/CRT glass to foreign destination failed to submit notification D V o R D COS <br /> 717 CCR 66273.32(b) UWH fail Dd to obtain an ID number from DTSC prior to accumulating>5000kg of non-RCRA UW D V D R D COS <br /> 718 CCR 66273.32(d) Failure o a UW handier to submit a complete annual report to DTSC D V D R D COS <br /> 719 CCR 66273.38 Failure o UW handler to transfer UW to the appropriate destination facility D V D R D COS <br /> 720 CCR 66273.31(a) UW hanc ler caused improper disposal of UW D V D R D COS <br /> 721 CCR 66273.8(b) Conditior ally exempt small quantity UW generator caused improper disposal of UW D V ❑R D COS <br /> Appliance Recycler <br /> 801 HSC 25211.4 Failure to obtain Certified Appliance Recycler certification(CAR) D V D R D COS <br /> 802 HSC 25211.2,25211.3 Failure o a CAR to provide docs that materials that require special handling have been removed D V D R D COS <br /> 803 HSC 25212 Failure o a CAR to properly remove and dispose of all materials that require special handling D V D R D COS <br /> Other Violations <br /> 3010 See below Unlisted dministration/Documentation violation D V D R D COS <br /> 3020 See below Unlisted Training violation D V D R D COS <br /> 3030 See below UnlistedOperations/Mai ntenanee violation D V o R D COS <br /> 3040 See below UnlistedRelease/Leaks/Spills violation D V D R D COS <br /> 3050 See below UnlistedAbandonment/illegal Disposal/Unauthorized Treatment violation D V D R D COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> FA0002321 PRO521299 SCO01 10/03/2018 <br /> EHD 22-01 Rev.09/22/16 Page 3 of 5 Small Quantity Hazardous Waste Generator OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.