Nitrate Loading Calculations: <br />Variable Value Units Description <br />Q 840 gallons per day Effluent flow rate from report <br />Nw 35 mg/L-N Effluent stream concentration from report <br />A 2.58 acres Site area from report <br />Nb 0.3 mg/L-N Concentration of rain water from report <br />d 0.25 constant Denitrification factor from report <br />R 12.60 inches per year Recharge rate of rainfall from report <br />W 4.4 inches per year Uniform waste water loading for site calculation result <br />Nc 7.0 mg/L-N RESULT: Long-term average concentration of percolating effluent <br />Find Variable (W): <br />(VV) = (Q) x 1 ft3 x 365 day(s) x 1 acre x 12 in x 1 site <br />yr day 7.48 gal 1 year 43,560 ft2 1 ft (A) acre(s) <br />4.38 in/yr (site) = 840 gal/day x (1 cu-ft / 7.48 gals) x (365 days/ 1 year) x (1 acre / 43,560 sq-ft) x (12 in / 1 ft) x (1 site / 2.58 acres) <br />Hantzsche-Fennemore Equation (Nc): <br />Nc = VVN(1-d)+RNI, <br />W+R <br />6.99 mg/L-N = ((4.38 in/yr x 35 mg/L-N x (1 -0.25)) + (12.6 in/yr x 0.3mg/L-N))/ (4.38 in/yr + 12.6 in/yr) <br />Assumptions: <br />Total nitrogen concentration of influent waste stream is 35 mg/L-N If different influent concentrations exist, use weighted average <br />Fraction of nitrate-N loss due to denitrification in the soil is 25%. <br />Estimated deep percolation of rainfall is 12.6 in/yr. <br />Background nitrate-N concentration of rainfall is 0.3 mg/L-N. <br />Nitrate Loading Calculation <br />Wutzke Property <br />21600 N. Kennefick Rd. <br />Acampo, CA <br />Plate No.: 15 <br />Project No: 1934 <br /> <br />LIVE OAK <br />GEO ENVIRONMENTAL INC. <br />Date: July 23, 2019 <br />