Laserfiche WebLink
Preparation and Presaturation of Percolation Test Holes <br /> After the boring was advanced by hand auger and the soils logged, the test hole was <br /> completed for the percolation test. Approximately two inches of pea gravel were placed <br /> in the bottom of the open soil boring, followed by a 2.0-inch diameter PVC pipe with <br /> perforations on the bottom. Pea gravel was then used to backfill a few inches of the <br /> annular space. <br /> Live Oak presaturated the percolation test hole approximately 24 hours prior to the <br /> percolation testing. The hole was filled with water to a height of 12 inches above the <br /> bottom of the boring for the presaturation. On the day of testing, the hole was found to <br /> be intact and dry. <br /> Percolation Test Procedure <br /> Live Oak conducted the percolation test for the boring on January 25, 2019. Due to <br /> initial percolation rates observed, a four-hour test was selected. Water level <br /> measurements were taken every 30 minutes during this four-hour period. The last 30 <br /> minutes of the test were observed by Naseem Ahmed, Registered Environmental <br /> Health Specialist at the San Joaquin County Environmental Health Department. <br /> An electronic well sounder with a depth accuracy of 1/100th foot was utilized for the <br /> water level measurements. The water level was measured against a fixed reference <br /> point on the well casing. Measurements were recorded on the data sheet in decimal <br /> feet. When necessary after measuring the water level, the hole was refilled with water <br /> to a level of six inches or more above the bottom of the hole. <br /> Percolation Test Results <br /> The completed percolation test form is included in Appendix 2 of this report. The form <br /> was signed by Mr. Ahmed of the San Joaquin County Environmental Health Department <br /> and indicates a percolation rate for the hole based on the final water drop observed. <br /> Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 36 and 42 inches; a satisfactory percolation <br /> rate for a shallow test is greater than or equal to 1 minute per inch (min/in) but less than <br /> or equal to 60 min/in drop. For the Site to utilize a standard septic system, one <br /> percolation test must demonstrate a satisfactory percolation rate within the proposed <br /> septic system disposal field. <br /> Details and results of the percolation test are summarized in the following table: <br /> LOGE 1849 Page 6 <br />