My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009 - 2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
1137
>
2300 - Underground Storage Tank Program
>
PR0530093
>
COMPLIANCE INFO_2009 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2019 2:35:07 PM
Creation date
11/19/2019 2:19:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2011
RECORD_ID
PR0530093
PE
2351
FACILITY_ID
FA0019793
FACILITY_NAME
CRUISERS MANTECA #29
STREET_NUMBER
1137
Direction
W
STREET_NAME
LATHROP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19724002
CURRENT_STATUS
01
SITE_LOCATION
1137 W LATHROP RD
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JAN JOAQUiN G-OUN'i s' <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 Iasi Main Streei. Siockton, Gaiiiornia 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.s*gov.org/ehd/unitiii.htmi <br /> UNDERGROUND STORAGE T ANK I[US T) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility address: Inspection Date: <br /> 1137 Lathrop Road, Manteca October 25, 2011 <br /> # Code Section VIOLATIONS V R <br /> HSC=CA Health&Safety Code; CCR=CA Code of Re ulations;V=Violation; RV=Re eat Violation V <br /> Designated operator monthly inspection: (c)(1)alarms not documented; (c)(2-4)spill containers, <br /> 23c CCR 2715(c), (e) UDCs, and sumps(if necessary)not inspected, (c)(5)required test dates not checked or noted; (c)(6) <br /> employee training not verified, (e)monthly inspection reports not maintained on site for at least 12 <br /> months <br /> 23d CCR 2715(f) Designated operator employee training: (1) not performed, (2)not current for at least one employee <br /> on site; 3 log not kept <br /> Monitoring equipment certification: (a)not performed annually; (d)test report not submitted within 30 <br /> 24 CCR 2638 days; (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation, <br /> repair, replacement,calibration,or certification,(f)performed, and failed to affix a tag/sticker on each <br /> monitoring equipment com onent that was certified, repaired, or replaced <br /> 25 HSC 25291(f) Annual line leak detector test not perfcrrned (M1) <br /> 26 HSC 25284.2 Annuals ill containment testing not performed <br /> 27 CCR 2636(f)(4) Annual line tightness test not performed if posibve shutdown or fail safe not present (M1) <br /> 23 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to permit (M2) <br /> conditions <br /> 29 CCR 2643(e) Biennial tightness test of gravity piping not perforrned re-Janus 1, 1984 (MI) <br /> 30 CCR 2643(d) Triennial line test for conventional suction piping not performed re-Janus 1 1984 Mt <br /> 31 HSC 25292.5 ELD testing not performed on a system located within 1000'of public well,or failures not repaired and <br /> _ ___ retested _____ _ <br /> 32 CCR 2661 Permit to re air UST s stem <br /> not obtained <br /> 33 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 34 HSC 25298(b Permit to temporarily close UST system not obtained <br /> 35 HSC 25298(c) Permit to close UST system not obtained <br /> 36 HSC 25299(f)I(2) Tampering with or disabling leak detection devices or alarms <br /> 37 HSC 25298(a) Illegally abandoned LIST system <br /> 38 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br /> 39 CCR 263 1.1 a UST system is not compatible with the substance stored <br /> _ _ Emergency generator systems <br /> 40 CCR 2636 6 Emer enc generator monitorin system not checked dailyor I not kept if no leak detector (M1y <br /> 41 HSG 25281.5(b 3 Unburied fuel piping not visu_a!ly inspected_at least monthly or log not kept <br /> AB 1702(2003-2004) HSC 25290.2(installed between 07101/03 and 06/30104) <br /> VPH Systems HSC 25290.1 installed on or after 07/01/04 <br /> Compatibility and permeability.requirements. (a)UST system is not compatible with the substance <br /> 42 CCR 2631.1 stored.(b)results of the compatibility and permeability testing requirements listed in subsections CCR <br /> 2631 b)and d for a UST system installed after Jul 1,2004,were not submitted <br /> 43 HSC 25290.1(c)(t} prima rycontainment not liquid or vapor tight <br /> HSC 25290.2(c)(1) <br /> 44 HSC 25290.1(c)(2) Secondary containment not liquid or vapor tight X <br /> HSC 25290.2(c 2) <br /> 45 HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br /> HSC 25290.2 c 3 <br /> 46 HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment,or (M1) <br /> HSC 25290.2(d) the entrV of liquid or vapor from the primary containment into the secondary containment <br /> Interstitial liquid measurement method, constant vacuum, or constant pressure in the interstitial (mi) <br /> 47 HSC 25290.1(e} space of the UST system not maintained <br /> HSC 25290.10) UST system not tested by one of the following methods prior to use: (1)Enhanced leak detection; (2) <br /> 48 NSC 25290.2(1) inert gas pressure test approved by SWRCB, (3)test method deemed equivalent to(1)or(2)by the <br /> SVVRCB <br /> Other violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> EHD inspector: ?hone <br /> " l ! �� Septic system:4a,6 Serves 20 people/day <br /> Received by: Title: Receives other than sanitary waste <br /> Other disposal methods_ <br /> Dry veils/French Drains <br /> =F;^220?_002 RPV n;;'. Va'a`j I_ICT INCP_;_TjCN REPf1RT <br />
The URL can be used to link to this page
Your browser does not support the video tag.