Laserfiche WebLink
Time In: <br /> Time Out: <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br /> • .. �P Telephone:(209)468-3420 Fax:(209)464-0138 Web:www.siclov.orq/ehd <br /> Underground Storage Tank Program Service Request Inspection Report <br /> Name of Facility: CRUISERS MANTECA#29 Date: 10/18/2018 <br /> Address: 1137 W LATHROP RD , MANTECA 95336 <br /> Requestor: MARTY WEITHMAN, SERVICE STATION SYSTEMS INC Telephone: (408)213-6038 <br /> Program Element: 2308-UST RETROFIT Request#: SR0079577 <br /> Inspection Type: 298-UST RETROFIT REPAIR INSPECTION <br /> Onsite Service Technician: Joshua Duke ICC Service Tech/Installer Exp. Date: 04/05/2019 <br /> Manufacturer training: Veeder Root, 11/18/19; SBravo, 09/28/20 <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> NOTES <br /> On site to witness the following: <br /> -Integrity testing of the 87 STP sump after repairs prior to brine addition per the manufacturer's installation instructions, brine <br /> type verification,and brine addition.The 87 product STP was put under 13 inches of mercury for 60 minutes.Test passed. <br /> -Verify installation of the new 87 product STP Bravo test port. Installed per manufacturer's installation instructions. Passed. <br /> -Verify brine communication inside 87 product STP sump. Passed <br /> -Verify sensor functionality of the monitoring system for the 87 product smart sensor, 91 product vent line sensor and 87 <br /> product STP sump brine sensor.All test passed. <br /> Note:A small amount of liquid was observed in the 91 product vent line smart sensor.The service technician stated that it <br /> could be due to the siphon check valve starting to go bad but the functionality of the sensor was tested and in working <br /> conditions. Furthermore while inspector was on site, S7-Diesel product smart sensor was in no vacuum alarm and L5-Diesel <br /> product STP brine sensor was in low liquid alarm.The service technician was investigating the alarms when the inspector left <br /> the site. <br /> This service request is completed at this time. <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the Califomia Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: Joshua Duke, Service Technician <br /> EH Specialist: ZUNA BARKER Phone: (209)953-7311 <br /> FA0019793 SR0079577 SC298 10/18/2018 <br /> EHD 23-01 Rev.06/30/15 Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />