My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
1137
>
2300 - Underground Storage Tank Program
>
PR0530093
>
INSTALL_2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2019 2:35:19 PM
Creation date
11/19/2019 2:57:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2009
RECORD_ID
PR0530093
PE
2351
FACILITY_ID
FA0019793
FACILITY_NAME
CRUISERS MANTECA #29
STREET_NUMBER
1137
Direction
W
STREET_NAME
LATHROP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19724002
CURRENT_STATUS
01
SITE_LOCATION
1137 W LATHROP RD
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Piping information continued- <br /> Check <br /> Box Code <br /> Section <br /> ❑ z5290.1(c)(1) Piping compatible with material intended to be stored. <br /> 25290.2(c)(1) <br /> ❑ 23 CCR Design and construction of piping approved by independent testing organization(e.g.UL). <br /> 2631 b <br /> ❑ Piping,including vent lines,sloped toward tanks with minimum 1/4 inch sloe per 1 foot of run. <br /> HSC <br /> ❑ 25290.1(k) <br /> 25290.2(D&O) Vapor recovery,fill riser,and vent line piping are.secondarily contained. <br /> G. OVERSPILL/OVERFILL PREVENTION: <br /> check <br /> Box Code <br /> Section <br /> ❑ 23 CCR Overspill containment having minimum capacity of 5 gallons provided at each tank fill location. <br /> 2635(b) Manufacturer Model <br /> Approved overfill prevention device provided at each tank fill location. <br /> Choose One of the following methods: <br /> Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br /> triggering an audible visual alarm <br /> Restrict delivery of flow to the tank at least 30 minutes before the tank overfills,provided the <br /> restriction occurs when the tank is filled to no more than 95 percent capacity;and activate an audible <br /> ❑ 23 CCR alarm at least five minutes before the tank overfills <br /> 2635(b)(2) <br /> Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br /> capacity. <br /> Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br /> tank are exposed to product due to overfilling. <br /> Manufacturer Model 2 <br /> M5 Sc(4�S <br /> H. CORROSION PROTECTION: <br /> Check- <br /> Box <br /> heckBox Code <br /> Section <br /> Fiberglass reinforced plastic(FRP) <br /> Piping corrosion protection: Steel with cathodic protection or impressed current <br /> ® 23 CCR Steel isolated from contact with backfill <br /> 2636(b) <br /> FRP or equivalent non-metallic exterior coatings or coverings <br /> Tank corrosion protection: Sacrificial Anode <br /> LA 23 CCR Steel tank with field installed cathodic protection or impressed <br /> 2635(a)(2) <br /> current / <br /> ❑ Tie-downs,when used,constructed of non-corrosive material or coated steel. A A <br /> Revised 07/31/08 7 <br />