LG 150-2 Enclosure <br /> Summary Table <br /> Summary of Underground Storage Tank Overfill Prevention Options <br /> Health &Safety Code(H&SC),Sections 25281.5,25290.1, 25290.2, 25291, and 25292 <br /> CCR,Title 23, Division 3, Chapter 16,Sections 2635,2636,and 2665 <br /> H&SC 25291 H&SC 25290.1& <br /> 25290.2 <br /> Overfill Over fill Product Level Regulatory Venr/Tank Riser Ventlfcu:k Riser Pipilrg Vent/lank Riser Prying <br /> ;i;`dirys Prevention System Prevention Citation Piping Subject to Subject to Secondary Subject to Secondary <br /> �•.=-:" Mechanism CCR, Title 23 Corrosion Containment4? Containment? <br /> "Examples" Protection? §2636(a)(1) <br /> 2636(b <br /> Flow restrictor Ball float' 90% §2635(b)(2)(A) YES YES4 YES <br /> if - - - - -- _ _ - - - - - -- - - - - -- ---- --- - - - - - <br /> 2 -•---.-•-•- •-------------------------------------------------------------•----------- Y <br /> i-' - - Audible and a l <br /> External alarni 90% §2635(b)(2)(A) YES YES YES <br /> a, visual alarm <br /> g 'x At least 30 minutes <br /> "may Ball float' before tank overfills & <br /> filled to no more than <br /> Flow restrictor And 95%of tank capacity §2635(b)(2)(B) NO' NOS YES <br /> (_!�y At least five minutes <br /> External alarm <br /> before tank overfills <br /> e Positive shut off Fill tube? valve 11 s <br /> ( )( )(� <br /> i ` valve (flapper) 95`p0 §2635 6 2 NO' NO YES <br /> b; Positive shut off Fill tube?valve §2635(b)(2)(D) YES" <br /> valve (fla er Below tank top Fittings YES YES <br /> pP ) <br /> 1 In order to provide proper flow restriction,a ball float is required under all open risers except the fil I riser and automatic tank gauging port. <br /> 2 If both types of overfill prevention systems(ball float and fill tube valve)are installed,the ball float may interfere with the operation of the fill tube valve if the ball <br /> float is installed lower than the fill tube valve. Therefore,the ball float should be installed at a higher level than the fill tube valve so that the fill tube valve is <br /> activated prior to any flow restriction. <br /> 'Corrosion protection is not required in this case because the vent/tank riser piping is exempt from the definition of"pipe"pursuant to H&SC§25281.5. However,it <br /> is a best management practice to provide corrosion protection for all corrodible piping in contact with the backfill. <br /> 4 Secondary containment is required at post July 1, 1987 installations because with this type of overfill prevention the components do not meet the exemption criteria <br /> of Section 2636(a)(1),CCR- <br /> ' <br /> CR' Single-walled components of UST systems may be a source of product or vapor releases to the subsurface environment,even if they do not routinely contain product. <br /> Therefore,we recommend installation of secondary containment on all UST components,including those currently exempt from this requirement. <br />