My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012 - 2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
1137
>
2300 - Underground Storage Tank Program
>
PR0530093
>
COMPLIANCE INFO_2012 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2019 2:40:59 PM
Creation date
11/20/2019 8:45:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2016
RECORD_ID
PR0530093
PE
2351
FACILITY_ID
FA0019793
FACILITY_NAME
CRUISERS MANTECA #29
STREET_NUMBER
1137
Direction
W
STREET_NAME
LATHROP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19724002
CURRENT_STATUS
01
SITE_LOCATION
1137 W LATHROP RD
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
436
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Q 3:DIESEL OUTPUT RELAY SETUP <br /> TYP:2.0i3.0IN FIBERGLASS <br /> 2.OIN DIA LEN: 500 FEET L 8:DISP 1-2 BRINE R 3:OVER FILL <br /> TRI-STATE (SINGLE FLOAT) TYPE: <br /> 3.OIN DIA LEN: 0 FEET CATEGORY : DISPENSER PAN STANDARD <br /> NORMALLY OPEN <br /> SHUTDOWN RATE: 3.0 GPH <br /> LOW PRESSURE SHUTOFF:NO TANK #: NONE <br /> LOW PRESSURE : 0 PSI L 9:DISP 1-2 LIQUID <br /> TRI-STATE (SINGLE FLOAT) IN-TANK ALARMS <br /> T PENSEEL MODE: CATEGORY : DISPENSER PAN <br /> DISPENSE ALL:OVERFILL ALARM <br /> STANDARD ALL:HIGH PRODUCT ALARM <br /> SENSOR: HIGH PRESSURE ALL:MAX PRODUCT ALARM <br /> PRESSURE OFFSET: O.OPSI L1O:DISP 3-4 BRINE <br /> MECHANICAL BLENDER: NO TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : DISPENSER PAN <br /> Lll :,,ISP 3-4 LIQUID <br /> TRI-STATE (SINGLE FLOAT) <br /> CATEGORY": DISPENSER PAN <br /> PLLD LINE DISABLE SETUP <br /> L12:DIS 5-6 BRINE <br /> TRI-STATE (SINGLE FLOAT) Q 1 :UNLEADED <br /> LINE LEAK LOCKOUT SETUP CATEGORY : DISPENSER PAN <br /> _ - - _ - _ f- - - - - - LIQUID SENSOR ALMS <br /> LOCKOUT SCHEDULE L 1 :FUEL ALARM <br /> DAILY L13:DISP 5-6 LIQUID L 2:FUEL ALARM <br /> START TIME: DISABLED TRI-STATE (SINGLE FLOAT) L 9:FUEL ALARM <br /> STOP TIME DISABLED CATEGORY : DISPENSER PAN Lll :FUEL ALARM <br /> L13:FUEL ALARM <br /> L15:FUEL ALARM <br /> L17:FUEL ALARM <br /> L14:DISP 7-8 BRINE L18:FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) L 1 :SENS0R OUT ALARM <br /> CATEGORY : DISPENSER PAN L 2:SENS0R OUT ALARM <br /> L 9:SENSOR OUT ALARM <br /> L11 :SENS0R OUT ALARM <br /> L13:SENSOR OUT ALARM <br /> L15:DISP 7-8 LIQUID L15:SENS0R OUT ALARM <br /> TRI-STATE (SINGLE FLOAT) L17:SENS0R OUT ALARM <br /> CATEGORY : DISPENSER PAN L18:SENSOR OUT ALARM <br /> LIQUID SENSOR SETUP L 1 :SH0RT ALARM <br /> _ _ - - - - - - - - - - L 2:SH0RT ALARM <br /> L 9:SH0RT ALARM <br /> L 1 :87 STP COMBO L16:DISP 9-10 BRINE L11 :SHORT ALARM <br /> DW SUMP 2-1 TRI-STATE (SINGLE FLOAT) L13:SH0RT ALARM <br /> CATEGORY : STP SUMP CATEGORY : DISPENSER PAN L15:SH0RT ALARM <br /> L17:SH0RT ALARM <br /> L18:SH0RT ALARM <br /> L 2:87 FILLCOMBO <br /> DW SUMP 2-1 L17:DISP 9-10 LIQUID SMARTSENSOR ALARMS <br /> CATEGORY : PIPING SUMP TRI-STATE (SINGLE FLOAT) s 1 :HIGH LIQUID ALARM <br /> CATEGORY : DISPENSER PAN ISD SITE ALARMS <br /> L 3:91 STP COMBO ISD GROSS PRES FAIL <br /> DW SUMP 2-1 ISD DEGRD PRES FAIL <br /> CATEGORY : STP SUMP L18:DISP 11-12 LIQUID ISD VAPOR LEAK FAIL <br /> TRI-STATE (SINGLE FLOAT) ISD VP PRES FAIL <br /> CATEGORY : DISPENSER PAN ISD VP STATUS,FAIL <br /> L 4:91 FILL COMBO MISSING RELAY SETUP <br /> DW SUMP 2-1 MISSING HOSE SETUP <br /> CATEGORY : PIPING SUMP MISSING TANK SETUP <br /> L19:DISP 11-12 BRINE MISS VAPOR FLOW MTR <br /> L 5:DSL STP COMBO TRI-STATE (SINGLE FLOAT) MISS VAPOR PRES SEN <br /> UW SUMP 2-1 CATEGORY DISPENSER PAN ISD SETUP FAIL <br /> CATEGORY : STP SUMP ISD SENSOR OUT FAIL <br /> ISD HOSE ALARMS <br /> L 6:DSL FILLCOMBO ALL:GROSS COLLECT FAIL <br /> DW SUMP 2-1 ALL:DEGRD COLLECT FAIL <br /> CATEGORY : PIPING SUMP ALL:FLOW COLLECT FAIL <br /> ALL:AIRFLOW MTR SETUP <br /> L 7:VENT COX COMBO FMC ALARMS <br /> DW SUMP 2-1 VP EMISSIONS FAIL <br /> CATEGORY : PIPING SUMP VP PRESSURE FAIL <br /> VP DUTY CYCLE FAIL <br /> PMC SENSOR FAULT <br />