COMPLIANCE INFO_2012 - 2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
1137
>
2300 - Underground Storage Tank Program
>
PR0530093
>
COMPLIANCE INFO_2012 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2019 2:40:59 PM
Creation date
11/20/2019 8:45:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2016
RECORD_ID
PR0530093
PE
2351
FACILITY_ID
FA0019793
FACILITY_NAME
CRUISERS MANTECA #29
STREET_NUMBER
1137
Direction
W
STREET_NAME
LATHROP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19724002
CURRENT_STATUS
01
SITE_LOCATION
1137 W LATHROP RD
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
436
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECENE-D <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT SEP 2 0 L013 <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.si4ov.oro/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Name:+ty Facility <br /> Name: Cruisers#29 Address: 1137 W Lathrop Rd, Manteca Ins'.cion Aug5, 2013 <br /> Date g <br /> VIOLATIONS <br /> # C1 C2 I M Code Section NSC=CA Health and Safety Code.CFR=Code of Fcder�el Regulations <br /> C1=Glass 1 v'1o1etion:C2-Class 2 violation.M=_Miner violation <br /> Non-Pressurized Piping(continued) <br /> 702 1 1 ICCR2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) M1 <br /> 703 CCR 2643(4) Triennial line test for conventional suction-piping not erfornted ( ) <br /> P P 19 P (pre-January 1, 1984) fM11 <br /> Other violations <br /> 999 Other. See attached"Continuation-Official Inspection Report'for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Onsite to conduct a routine UST inspection and observe Monitoring System Certification conducted <br /> today. A checklist was left onsite at the time of inspection, and a complete report was delivered to the <br /> facility on August 21, 2013. A cold start inspection for the SR0067435 was also conducted on August 15, <br /> 2013 (post software upgrade on the Veeder Root system). All system functions were verified, a copy of <br /> the alarm history was submitted to the EHD. <br /> Class II Violations: (303, 313, 404, and 406): <br /> 303. The 87-octane STP sump sensor was located approximately 2-inches up the saddle of the tank <br /> sump, the 87 fill sump sensor was located approximately 2-feet up the saddle of the tank sump, and the <br /> diesel fill sump sensor was located approximately 1-foot up the saddle of the tank sump. These sensors <br /> were not located to detect a leak at the earliest opportunity. Monitoring equipment shall be maintained <br /> to be able to detect a leak at the earliest possible opportunity. The technician repositioned all the <br /> sensors to the lowest points of the respective sumps. CORRECTED. <br /> 313. The 91-octane spill container failed when tested. All spill containers shall have a minimum capacity <br /> of five gallons and be capable of containing a spill or overfill until it is detected or cleaned up. The <br /> technician replaced the outer O-ring of the spill container, retested and it passed. A retrofit verification <br /> with the inspector already onsite was filled out and a copy provided to the store manager at the time of <br /> the inspection. CORRECTED. <br /> 404. Water was found in the 87-octane fill sump (approximately 4 gallons), diesel fill sump <br /> (approximately 1 gallon), 87-octane STP (approximately 2 cups), 91 STP sump (approximately 1.5 <br /> quarts), and in the vent sump (approximately 0.5 cup). Technician removed the liquid from above <br /> sumps and retained for disposal. According to the reviewed site records, approximately 100-gallons was <br /> removed from the onsite sumps on 12-10-12, approximately 150-gallons were removed from the 87-fill <br /> sump on 12-26-12, and approximately 230-gallons were removed from the 87-fill sump on 01-08-13. <br /> Secondary containment shall be constructed to prevent any water intrusion into the system by <br /> precipitation, infiltration, or surface runoff. Immediately contact a properly licensed, trained, and certified <br /> contractor to address the water intrusion into the onsite sumps under permit and inspection of the EHD. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION ATA Y TIME AT EHD'S CURRENT HOURLY RATE. <br /> l"cpecmr Recmed BY Ttle <br /> ck- <br /> EHD 23-02 Rev 04/19/12 ag 3 UST!NSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.