My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012 - 2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
1137
>
2300 - Underground Storage Tank Program
>
PR0530093
>
COMPLIANCE INFO_2012 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2019 2:40:59 PM
Creation date
11/20/2019 8:45:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2016
RECORD_ID
PR0530093
PE
2351
FACILITY_ID
FA0019793
FACILITY_NAME
CRUISERS MANTECA #29
STREET_NUMBER
1137
Direction
W
STREET_NAME
LATHROP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19724002
CURRENT_STATUS
01
SITE_LOCATION
1137 W LATHROP RD
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
436
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NORMALLY OPEN L13:FUEL ALARM <br /> L15:FUEL ALARM <br /> TANK #: NONE L17:FUEL ALARM SMARTSENSOR SETUP <br /> L 18:F UEL ALARM - - - - - - - - - - - - <br /> L 3:SENSOR OUT ALARM <br /> IN-TANK ALARMS L 9:SENSOR OUT ALARM <br /> s 1 :87 PRODUCT UAC <br /> ALL:OVERFILL ALARM Lll :SENSOR OUT ALARM CATEGORY VAC SENSOR <br /> ALL:HIGH PRODUCT ALARM L13:SENSOR OUT ALARM PUMP #: <br /> ALL:MAX PRODUCT ALARM L15:SENSOR OUT ALARM Q 1 :UNLEADED <br /> L17:SENSOR OUT ALARM VOLUME: 212.0 GALLONS <br /> L18:SENSOR OUT ALARM RELIEF VALVE: : NO <br /> L 3:SHORT ALARM <br /> L 9:SHORT ALARM s 2:87 VENT VAC <br /> Lll :SHORT ALARM CATEGORY VAC SENSOR <br /> L13:SHORT ALARM PUMP #: <br /> L15:SHORT ALARM Q 1 :UNLEADED <br /> L17:SHORT ALARM VOLUME: 42.0 GALLONS <br /> 1_18:SHORT ALARM RELIEF VALVE: : NO <br /> SMARTSENSOR ALARMS s 3:87 ANNULAR VAC <br /> PLLD LINE DISABLE SETUP s 5:HIGH LIQUID ALARM CATEGORY VAC SENSOR <br /> - - _ - - - - - - - - - PUMP #: <br /> ISD SITE ALARMS Q 1 :UNLEADED <br /> Q 1 :UNLEADED ISD GROSS PRES FAIL VOLUME: 220.0 GALLONS <br /> ISD DEGRD PRES FAIL RELIEF VALVE: : NO <br /> LIQUID SENSOR ALMS ISD—VAPOR LEAK FAIL <br /> L 1 :FUEL ALARM ISD VP PRES FAIL s 4:87 VAPOR VAC <br /> L 2:FUEL ALARM ISD VP STATUS FAIL CATEGORY VAC SENSOR <br /> L 9:FUEL ALARM MISSING RELAY SETUP PUMP #: <br /> Lll :FUEL ALARM MISSING HOSE SETUP Q I :UNLEADED <br /> L13:FUEL ALARM MISSING TANK SETUP VOLUME: 253.0 GALLONS <br /> L15:FUEL ALARM MISS VAPOR FLOW MTR RELIEF VALVE: : NO <br /> L17:FUEL ALARM MISS VAPOR PRES SEN <br /> L18:FUEL ALARM ISD SETUP FAIL s 5:91 PRODUCT VAC <br /> L 1 :SENSOR OUT ALARM CATEGORY VAC SENSOR <br /> L 2:SENSOR OUT ALARM ISD SENSOR OUT FAIL PUMP #: <br /> L 9:SENSOR OUT ALARM PC-ISD FAILURE Q 2:PREMIUM <br /> Lll :SENSOR OUT ALARM VOLUME: 212.0 GALLONS <br /> L13:SENSOR OUT ALARM ISD HOSE ALARMS RELIEF VALVE: : NO <br /> L15:SENSOR OUT ALARM ALL:GROSS COLLECT FAIL <br /> L17:SENSOR OUT ALARM ALL:DEGRD COLLECT FAIL s 6:91 VENT VAC <br /> L18:SENSOR OUT ALARM ALL:FLOW COLLECT FAIL CATEGORY VAC SENSOR <br /> L 1 :SHORT ALARM ALL:AIRFLOW MTR SETUP PUMP #: <br /> L 2:SHORT ALARM Q 2:PREMIUM <br /> L 9:SHORT ALARM PMC ALARMS VOLUME: 45.0 GALLONS <br /> LII :SHORT ALARM VP RUNTIME FAULT RELIEF VALVE: : NO <br /> L13:SHORT ALARM VP EMISSIONS FAIL <br /> L15:SHORT ALARM VP PRESSURE FAIL s 7:DSL PRODUCT UAC <br /> L17:SHORT ALARM VP DUTY CYCLE FAIL CATEGORY VAC SENSOR <br /> L18:SHORT ALARM PMC SETUP FAIL PUMP #: <br /> Q 3:DIESEL <br /> SMARTSENSOR ALARMS Q 3:DIESEL VOLUME: 220.0 GALLONS <br /> s 1 :HIGH LIQUID ALARM RELIEF VALVE: : NO <br /> LIQUID SENSOR ALMS <br /> ISD SITE ALARMS L 5:FUEL ALARM s B:ATM <br /> ISD CROSS PRES FAIL L 9:FUEL ALARM CATEGORY ATM P SENSOR <br /> ISD DEGRD FRES FAIL Lll :FUEL ALARM <br /> ISD VAPOR LEAK FAIL L13:FUEL ALARM s 9:DSL VENT VAC <br /> ISD VP PRES FAIL L15:FUEL ALARM CATEGORY VAC SENSOR <br /> ISD VP STATUS FAIL L17:FUEL ALARM PUMP #: <br /> MISSING RELAY SETUP L18:FUEL ALARM Q 3:DIESEL <br /> MISSING HOSE SETUP L 5:SENSOR OUT ALARM VOLUME: 45.0 GALLONS <br /> MISSING TANK SETUP L 9:SENSOR OUT ALARM RELIEF VALVE: : NO <br /> Lll :SENSOR OUT ALARM <br /> MISS VAPOR FLOW MTR L13:SENSOR OUT ALARM 510:DSL-91 ANNULAR VAC <br /> MISS VAPOR PRES SEN L15:SENSOR OUT ALARM CATEGORY UAC SENSOR <br /> ISD SETUP FAIL L17:SENSOR OUT ALARM PUMP #: <br /> ISD SENSOR OUT FAIL L18:SENSOR OUT ALARM Q 3:DIESEL <br /> L 5:SHORT ALARM VOLUME: 220.0 GALLONS <br /> ISD HOSE ALARMS L 9:SHORT ALARM RELIEF VALVE: : NO <br /> ALL:GROSS COLLECT FAIL L11 :SHORT ALARM <br /> ALL:DEGRD COLLECT FAIL L13:SHORT ALARM sll :1-2 AFM <br /> ALL:FLOW COLLECT FAIL L15:SHORT ALARM CATEGORY AIR FLOW METER <br /> ALL:AIRFLOW MTR SETUP L17:SHORT ALARM <br /> 1_18:SHORT ALARM sl2:3-4 AFM <br /> PMC ALARMS CATEGORY AIR FLOW METER <br /> VP EMISSIONS FAIL SMARTSENSOR ALARMS <br /> VP PRESSURE FAIL s 7:HIGH LIQUID ALARM sl3:5-6 AFM <br /> VP DUTY CYCLE FAIL CATEGORY AIR FLOW METER <br /> PMC SENSOR FAULT sl4:7-8 AFM <br /> Q 2:PREMIUM CATEGORY AIR FLOW METER <br /> LIQUID SENSOR ALMS 515:9-10 AFM <br /> L 3:FUEL ALARM CATEGORY AIR FLOW METER <br /> L 9:FUEL ALARM �1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.