My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012 - 2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
1137
>
2300 - Underground Storage Tank Program
>
PR0530093
>
COMPLIANCE INFO_2012 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2019 2:40:59 PM
Creation date
11/20/2019 8:45:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2016
RECORD_ID
PR0530093
PE
2351
FACILITY_ID
FA0019793
FACILITY_NAME
CRUISERS MANTECA #29
STREET_NUMBER
1137
Direction
W
STREET_NAME
LATHROP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19724002
CURRENT_STATUS
01
SITE_LOCATION
1137 W LATHROP RD
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
436
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONIS RING SYSTEM CERTIR ,TION <br /> For Use By All Jurisdictions R'ithin the State of California <br /> Authorio,Cited:-Chapter 6.7, Health and Safety'Code; Chapter 16, .Division 3, Title 23, California Code of Regulations <br /> This forret must be used to d*rcumeatAesting and servicing of monitoring equipment, if mor440_411 <br /> _+• F +*-�i se azate certification or to op rt must be grepartd_' each +it rim sv contr a el by the kcchttilOitfn_v�ti t7fAtms the work <br /> A.copy of this forma must be provided to the tank system owner/operator. The owner/operator must submit a copy of` i o } local agency <br /> regulating UST systems within 30 days of test date.-kms <br /> AUG 16 2013 <br /> A. General Information gy,�jBQNMRNTAL <br /> Facility Nanle: Cruisers <br /> Site Address: 1137 W. Lathrpp City: Manteca Zip: 95 <br /> Facility Contact Person: TYRONE Contact Phone No.: (209) 824-2760 <br /> Make/Model of Nionitoring System: TLS-350 Date of Testing/Servicing: 8/15/2013 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific a ui ment ins ected/servicedi: <br /> Tank iD: 87 Tank ID: 91 <br /> ®In-Tank Gauging Probe. Model: VEEDER ROOT ®In-Tank Gauging Probe. Model: VEEDER ROOT I, <br /> ®annular Space or Vault Sensor. Model: 420 ! 2_�knnular Space or Vault Sensor. Model: 420 <br /> (�Piping Sump/Trench Sensors) Model: 208 _ 0 Piping Sump/Trench Sensor(s). Model: 208 <br /> ®Fill Sump Sensor(s)- Model: 206 N Fill Sump Sensor(s), Modal: 208 <br /> El Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ®Electronic Line Lcak Detector. Model: VEEDER ROOT % �i 1 lectronic Line Leak Detector. Model: VVEDER ROOT <br /> Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ®Other(specify equipment tl,pe and model in Section E on Page 2). ( Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: DiESEL Tank 1D: <br /> ®Ira-Tank Gaugingg Probe. Model: VEEDER ROOT ElIn-TankGauging Probe. Model:El A <br /> ®Annular Spare or Vault Sensor. Model: 420 nnuiw space or Vault Sensor. Model: <br /> E Piping Sump/Trench Sensor(s). Model: 208 ❑Piping Sump/Trench Sensor(s). Model: <br /> M Fill Sump Scmor(s). Model: 208 ❑Fill Sump Sensor(s). Model: <br /> ©Mechanical Line teak Detector. Model: ©Mechanical Line Leak Detector. Model: <br /> ®Electronic Line Leak Detector. Model' VEEDER ROOT _ ❑Electronic Line leak Detactnr. Model <br /> ❑Tank overfill/High-Level Sensor. Model: O�Tannker+il/High-Leel Sensor. Model;Other(specify equipment type and model in§ .tion Eon Page 2). ❑ pecify equipment type and model in Section Eon Page 2). <br /> Dispenser ID: 1-2 .Dispenser lD. 3-4 <br /> ®Dispenser Containment Sensor(s). Model: 208 ®Dispenser Containrnant Sensors}, Model: 208 <br /> ®Shear Valve(s). ®Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ©Dispenser Containment Float(s)and Chain(s). <br /> Dispenser TD, 5-6 Dispenser ID: 7-8 <br /> El Dispenser Containment Sensor(s)- Model: 208 ®Dispenser Containment Scmor(s). Model- 208 <br /> ®shear Valvc(s). ®Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Floats)and Chain(s). <br /> Dispenser led: 9-10 Dispenser ID: 11-12 <br /> ®Dispenser Containment Sensor(s) Model; 208 Q Dispenser Containment Sensor(s). Model 208 <br /> ( Shear Valve(s) 0 Shear Valve(s). <br /> Dispenser Containment Floats)and.Chain(s). ❑Dispenser Containment Floats)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form, Include information for every tank and dispenser at the facility. <br /> C. Cer>tlflCation -l certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines, attached to this Certification is information (e.g, manufacturers' checklists) necessary to verity that this information is <br /> correct and a otylan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have <br /> also attached a copy of the report;(check all than apple): ®System set-up Alarms h' tory repo � <br /> Technician Name.(print): RUBEN GALINDO Signai,J e: Y. <br /> Cettification No.:. 838100 1.iccnse.NO-: <br /> Testing Co>xlpany Name: LC SERVICES Photate <br /> o.: ��444-1730 <br /> Testing Company Address: 388' N.VALENTINE FRESNO CA. 93722 of Testing/Servicing: 811512013 <br /> UN-036-1/6 www.unido<s.org Rev.01/17/08 <br />