COMPLIANCE INFO_2012 - 2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
1137
>
2300 - Underground Storage Tank Program
>
PR0530093
>
COMPLIANCE INFO_2012 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2019 2:40:59 PM
Creation date
11/20/2019 8:45:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2016
RECORD_ID
PR0530093
PE
2351
FACILITY_ID
FA0019793
FACILITY_NAME
CRUISERS MANTECA #29
STREET_NUMBER
1137
Direction
W
STREET_NAME
LATHROP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19724002
CURRENT_STATUS
01
SITE_LOCATION
1137 W LATHROP RD
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
436
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.s�oq v.or4/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CRUISERS MANTECA#29 1 1137 W LATHROP RD, MANTECA 14, 2016 <br /> UST System Observations <br /> 326 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 327 HSC 25298(b) Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 328 HSC 25298(c) Failed to comply with permanent closure requirements ❑V ❑R ❑COS <br /> 329 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system ❑V ❑R ❑COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation ❑V n R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The following sump sensors were located up the sump saddles and off the lowest points of their respective sumps, <br /> and not located to detect a leak at the earliest opportunity: diesel fill sump sensor (4-6 inches up the sump saddle), 91 <br /> fill sump sensor (10-12 inches up the sump saddle), and diesel STP sump (6-8 inches up the sump saddle). <br /> Monitoring equipment shall be maintained to be able to detect a leak at the earliest possible opportunity. The sensor <br /> was relocated to the lowest point of the sump by the service technician. Ensure that all monitoring equipment is <br /> maintained to detect a leak at the earliest opportunity. This violation was corrected onsite. <br /> This is a Class II violation. <br /> 314 HSC 25290.1, 25290.2, 25291 Failed to have secondary containment or secondary containment not tight. <br /> Liquid with some fuel odor (per the technician onsite) was found in the diesel STP sump, which had the newly <br /> installed Bravo Snap and Lock cover. L5 sensor (diesel STP sump brine sensor) was in alarm for low brine level at <br /> the time of inspection. The technician onsite added brine to the L5 sensor reservoir and "all functions normal' was <br /> observed at the panel. Also, yellow glue (similar to that used in the 87 fill sump)was observed around the sump <br /> penetration. The technician removed approximately 4-5 cups of liquid and placed it in the onsite hazardous waste <br /> container. Secondary containment shall be impervious to the liquid and vapor of the substance contained and <br /> constructed to prevent structural weakening as a result of contact with any hazardous substances released from the <br /> primary containment. Immediately contact a properly licensed, trained, and certified contractor to make repairs to <br /> the UST system under permit and inspection of the EHD, or immediately submit a permit for any un-permitted repairs <br /> already conducted on this sump. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Page 3of4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.