EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
1137
>
2300 - Underground Storage Tank Program
>
PR0530093
>
COMPLIANCE INFO_2012 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2019 2:40:59 PM
Creation date
11/20/2019 8:45:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2016
RECORD_ID
PR0530093
PE
2351
FACILITY_ID
FA0019793
FACILITY_NAME
CRUISERS MANTECA #29
STREET_NUMBER
1137
Direction
W
STREET_NAME
LATHROP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19724002
CURRENT_STATUS
01
SITE_LOCATION
1137 W LATHROP RD
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
436
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EIVEMonitoring System Certification Form: Addendum for Vacuum/Pressure Interstitial Sen D],Enc. it <br /> I. Results of Vacuum/Pressure Monitoring Equipment Testing 5EP 16 2016 <br /> This page should be used to document testing and servicing of vacuum and pressure interstitial sensor.,A copy of <br /> this form must be included with the Monitoring System Certification Form, which 6ii6st be provided;fQ a tank <br /> system owner/operator. The owner/operator must submit a copy of the Monitoring *k6ltt 6e-''kation F6 to the <br /> local agency regulating UST systems within 30 days of test date. <br /> ` Manufacturer: Veeder Root Model:--463 System Type:❑ Pressure;®Vacuum <br /> Sensor ID � '� <br /> � �� <br /> Component(s)Monitored by this Sensor: _ ` ---P-ROQ-,AND-SUMP-A-ND-VENT <br /> Sensor Functionality Test Result: WPass; ❑ Fail Interstitial Communication Test Result:® Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: !') \,-)Z✓ti <br /> Sensor Functionality Test Result:a Pass; ❑ Fail Interstitial Communication Test Result:❑ Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: i--) 191, <br /> 55 — Sensor Functionality Test Result: Pass; ❑ Fail Interstitial Communication Test Result:❑ Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: •� ( cJ� <br /> 51 _ Sensor Functionality Test Result: Pass; ❑ Fail Interstitial Communication Test Result:❑ Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: G1 !^d y <br /> Sensor Functionality Test Result: Pass; ❑ Fail Interstitial Communication Test Result:❑Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: `K' <br /> Sensor Functionality Test Result: Pass; ❑ Fail Interstitial Communication Test Result:❑ Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: 24, <br /> _ Sensor Functionality Test Result: Pass; ❑ Fail Interstitial Communication Test Result:❑ Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> _ Sensor Functionality Test Result: Pass; ❑ Fail Interstitial Communication Test Result:❑Pass; ❑ Fail <br /> Component(s)Monitored by this.Sensor: , <br /> dl Sensor Functionality Test Result: Pass; ❑ Fail I terstitial Communicatio Test Result:❑ Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> (� Sensor Functionality Test Result:n Pass; ❑ Fail Interstitial Communication Test Result:❑ Pass; ❑ Fail <br /> How was interstitial communication verified? <br /> ❑ Leak Introduced at Far End of Interstitial Space;' ❑ Gauge; ® Visual Inspection; ❑ Other(Describe in Sec.J, below) <br /> Vacuum was restored to operating levels in all interstitial spaces: ®Yes ❑No(If no, describe in Sec.J, below) <br /> J. Comments: <br /> Page of <br /> ' If the sensor successfully detects a simulated vacuum/pressure leak introduced in the interstitial space at the furthest point from the <br /> sensor,vacuum/pressure has been demonstrated to be communicating throughout the interstice. <br />
The URL can be used to link to this page
Your browser does not support the video tag.