• 5.0 CONCLUSIONS <br /> Groundwater continued to flow to the northeast during the quarter This has been the <br /> predominant flow direction throughout the investigation of the site <br /> Contaminant concentrations were stable during the second quarter of 2002 This is to be <br /> expected, although it has occurred rather infrequently at this site Based on historical trends, we <br /> expect concentrations to increase during the third quarter and reach their annual peak <br /> Soil, groundwater, and vapor data collected since 1995 all indicate that the center of the <br /> contaminant plume is located in the northwestern comer of the site, near the former dispenser <br /> island As Figure 6 shows, groundwater concentrations decrease away from this area and are <br /> between 100 and 1000 ppb over the rest of the site Contamination extends off site to the north <br /> and west and may be present as far south as the garage building The four additional monitoring <br /> wells that have previously been proposed and approved should be sufficient to delineate the <br /> margin of the plume in these areas, although VM-7 should be moved eastward along Main Street <br /> to better delineate the downgradient limit of contamination and VM-5 should be moved <br /> southeastward otito the Valley Motors property to better delineate the southern margin of the <br /> plume <br /> Valley Motors has now obtained a Faithful Performance bond, which the City, of Stockton <br /> requires before granting an Encroachment Permit to drill the additional monitoring wells It is <br /> anticipated that the permitting process will be completed in July and that drilling will take place <br /> in August 2002 , <br /> b <br /> 5 <br />