Laserfiche WebLink
48"ID COLLARS TYP. <br /> 9 " <br /> 9 <br /> ( ,7 7777=--::��l <br /> OFFSET CONSTRUCTION <br /> CIRCUMFERENTIAL SEAMS <br /> PLAN VIEW <br /> /V= IN,\ �\ND <br /> A B F DOUBLE BUTT CONSTRUCTION <br /> LOGITUDIAL SEAMS <br /> CSTEEL SECONDARY <br /> GLASSTEEI TANK <br /> >> I ps s gs s FIBERGLASS <br /> [� COMPOSITE <br /> II <br /> / \ ANNULAR SPACE <br /> MODERN <br /> CAL CALIFORNIA COMPANY \ I i I COLLARS i PRIMARY TANK <br /> OF O LOCATIONS <br /> STRAP <br /> LOCATIONS ENVIRONMENTAL TANK 16 <br /> L <br /> li I CONSTRUCTION DETAILS <br /> I modern II U INTERIOR:I <br /> r I I i i <br /> EXTERIOR: F'.R PN DEBRIS, UNPAINTED <br /> OMPOSOF <br /> DOUBLE T E S T I N G <br /> WALL I i i I <br /> \ THIS TANK ARRIVES AT THE JOBSITE UNDER VACUUM AND DOES NOT REQUIRE <br /> \ G L A S TE E L7 i I I STRIKER PLAT TYPICAL FURTHER INTEGRITY TESTS. IF JOBSITE PRESSURE TEST REQUIRED, AIR TEST <br /> UNDER ALL KINGS AT NOT MORE THAN 5 P.S.I. PRIMARY, (INNER) TANK TO BE TESTED ALONE. <br /> \ / SECONDARY TANK TO BE TESTED WITH PRESSURE IN PRIMARY TANK. AT NO <br /> _j TIME SHALL THE PRESSURE IN SECONDARY TANK. EXCEED THE PRESSURE IN <br /> THE PRIMARY TANK. HOLIDAY TEST F.R.P. COMPOSITE AT 35,000 VOLTS AT <br /> FACTORY. <br /> END VIEW <br /> SIDE VIEW <br /> © TANK SHALL MEET THE REQUIRMENTS OF NFPA 30 & 31. <br /> FIBERGLASS- COATED DOUBLE WALL STEEL UNDERGROUND STORAGE TANK SYSTEM INSTALLATION OTANK SHALL MEET THE REQUIRMENTS OF UFC. <br /> TANK SHALL MEET THE REQUIREMENTS OF SCAQMD <br /> FIBERGLASS COATED DOUBLE WALL STEEL TANKS. "MODERN WELDING-ENVIRO 16" SHOWN-ALTERNATE METHANOL COMPATIBILITY RULE 1170. <br /> EQUAL MANUFACTURERS TO BE FABRICATED TYPICAL & APPROVED BY SBC ENVIRONMENTAL MANAGEMENT. ❑ TANK SHALL BE BUILT TO THE SPECIFICATIONS OF ACT 100, <br /> SEE SITE SPECIFIC PLAN FOR CAPACITY AND QUANTITY OF TANKS. STEEL TANK INSTITUTE SPECIFICATION FOR THE FABRICATION OF <br /> FRP/CLAD UNDERGROUND TANKS. <br /> UNDERGROUND FUEL STORAGE TANK <br /> T3 TANK SHALL BEAR THE U.L. 1746 LISTING MARK FOR SECONDARY <br /> UNLESS OTHERWISE SPECIFIED, TANKS SHALL BE INSTALLED FOUR (4) FEET BELOW FINISHED YARD GRADE. TANKS SHALL BE CONTAINMENT COMPOSITE UNDERGROUND TANK FOR FLAMMABLE SW 1 046 <br /> LIQUIDIRM BASE OF 12" THICK CLEAN, WASHED, COMPACTED 3 4" PEA GRAVEL AND SURROUNDED ON ALL SIDES BY A PROTECTION <br /> STORAGE AND THE ACT 100 LABEL FOR CORROSION <br /> SET ON A F <br /> f PROTECTION OF UNDERGROUND STORAGE TANKS. <br /> MINIMUM THICKNESS OF 12" OF CLEAN, WASHED 3/4" PEA GRAVEL. AFTER PIPING HAS BEEN INSTALLED, INSPECTED AND REVISIONS / AUTHORIZATIONS <br /> TESTED, COMPLETE THE BACKFILLING WITH PEA GRAVEL. <br /> N0. TMDNS / AUTHORIZATIONS DATE BY <br /> AFTER TANKS ARE DELIVERED TO SITE, TANK MANUFACTURER OR SUPPLIER IS RESPONSIBLE FOR PERFORMING THE 35,000 SIZE 0 MASTER DRAWINGS 3/+/03 <br /> ;r VOLT HOLIDAY TEST AND REPAIR ANY HOLIDAYS DISCOVERED. THESE TESTS MUST BE WITNESSED BY ENVIRONMENTAL S DIAMETER LENGTH WEIGHT STRAPS SCHEDULE OF OPENINGS <br /> I Q PER CLIENT INSTRUCTIONS 11/12/03 DM <br /> MANAGEMENT AND LOCAL REGULATORY AGENCIES. � � : "., 4 , <br /> r` NO PRESSURE TEST IS REQUIRED BY THE CONTRACTOR IF THE TANK IS DELIVERED TO THE JOB SITE WITH VACUUM TEST, <br /> 1 ,000 65" 6'-6" 2,700# 2 <br /> MARK REQ D SIZE TYPE RATING REMARKS UPDATED TO 01/23/04 STANDARDS 2/23/04 DW <br /> APPLIED BY THE TANK MANUFACTURER, IN PROGRESS. 1 4" FNPT SPARE <br /> f NOTE: OTHER TANK DIAMETERS ARE AVAILABLE. <br /> REQUIRED INTEGRITY TANK (NON-VOLUMETRIC) VACUUM METHOD TO BE PERFORMED BY TANKNOLOGY CORPORATION. TANK TEST IR CONTACT MODERN WELDING AT (559) 275-9353 H 1 4" FNPT RETURN PROPRIETARY SBC INFORMATION <br /> RESULTS TO BE. SENT TO SBC ENVIRONMENTAL MANAGEMENT. G 1 4" FNPT VENT NOT FOR GENERAL USE OR DISCLOSURE OUTSIDE OF SBC <br /> _ n <br /> ��_ <br /> THIS INFORMATION MAY ONLY BE USED BY AUTHORIZED PERSONNEL OF <br /> ...... ' THE LOCAL GOVERNMENT AGENCY IN CONNECTION WITH APPLICATION FOR <br /> ...., .__._.,....• �� __...,x� ..._._.,_� .0 ...w , ._ F 1 4" FNPT SUPPLY <br /> _ PERMITS AND AUTHORIZATIONS FOR BUILDINGS, CONSTRUCTION, AND/ OR <br /> E 1 4" FNPT TLM ZONING CHANGES. <br /> D 1 4" FNPT SAMPLE PORT DRAWINGS PREPARED FOR <br /> C 1 4" FNPT SPARE CORPORATE <br /> B 1 4" FNPT FILL REAL ESTATE <br /> A 1 2" FNPT MONITOR <br /> ROJECT Trrt <br /> ESCA.LON <br /> 1812 COLEY AVENUE <br /> a . <br /> ESCALON, CALIFORNIA <br /> CLLC=ESCLCAl 1 UG-010 <br /> SHS TITLE: <br /> UNDERGROUND FUEL TANK <br /> SUCTION SYSTEM <br /> TANK ORIENTATION LIFTING LAYOUT <br /> ENGAGEMMT NUMBER: DATE: 09/16/03 SCALE: AS NOTED <br /> mTCONSULTING ENGINEERS DRAWN Br: DW CHECKED BY: TP <br /> 2880 Sunrise Boulevard SBC AUTHORIZATION: SHEEP 6 OR 8 SHEETS SHEET NO. <br /> Suite 206 <br /> Rancho Cordova, CA 95742 SBC DRAWING NO.: <br /> (916) 635-2444 F6 <br /> TAfT & ASSOCIATES, INC, (916) 635-2606 Fax <br />