My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_2003 PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLEY
>
1812
>
2300 - Underground Storage Tank Program
>
PR0231881
>
REMOVAL_2003 PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2019 8:33:14 AM
Creation date
11/21/2019 8:28:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
2003 PLANS
RECORD_ID
PR0231881
PE
2371
FACILITY_ID
FA0003946
FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
01
SITE_LOCATION
1812 Coley Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3/4" DUEL OIL_SUPPL_ <br /> SUCTION SYSTEM MATERIAL LIST <br /> & 1" FUEL OIL RETURN 5 <br /> 25 O 1,000 GALLON DOUBLE WALL STEEL, FIBERGLASS COATED COMPOSITE TANK. MODERN WELDING, ENIVRO 16. <br /> 20 O2 TANK & PIPING LEAK MONITOR/ELECTRONIC PRODUCT LEVEL JUCTION CONTROL BOX WITH GAUGE PROBE & 3 SENSORS. ALL <br /> 12 PROBES USED SHOULD BE FOR LJQUID DETECTION. <br /> FOR MULTIPLE QUANTITY OF TANKS: <br /> NOTE: ALL FILL BOXES ��' �� t 5 NUMBER TANKS W/3" BRASS <br /> TO BE INSTALLED ON NUMBERS SET IN CONCRETE O3 1 1/2* DOUBLE POPPET FOOT VALVE & EXTRACTOR ASSY. MORRISON 335A & 0,P,W.233E-404 . <br /> CENTERLINE OF TANK ADJACENT TO FILL BOX <br /> VENT LINE 4"x4"x2" 150# MALLEABLE IRON EXTRACTOR FITTING WITH PLUG MORRISQN 561. <br /> " <br /> r ,• r r Y• �5 48 CONTAINMENT SUMP WITH FIBERGLASS KIT PHS.-TITE #FG-4872. SUMPS TO BE INSTALLED USING CHOP GUN PER <br /> jrr�r PHI;-TITE SPECIFICATION (530-223-7400). <br /> rrlrrr <br /> 36" DIA. TLM/VENT MANHOLE. WITH ONE 13" ACCESS COVER PHIL-TITE_#TC 3600--OA0. <br /> 36" DIA. FILL MANHOLE WITH 5 GALLON SPILL BUCKET AND 18" SIDECAR. PHIL-TITE #.$C-3600-SW-SIDECAR-18. <br /> e_ (D <br /> O ,1 �fi jf " O WATERTIGHT SUMP SHIELD ASSEMBLY PHIL—TITE #FG-3433--WTSS. INCLUQES WTC ]� WTR-1013. WTC—BQQQ <br /> 2 SCH. 40 BLACK STEEL _ .WT — B. .:INSTAL.L,.PER-,.�IFB. •INSTAL ANION INSTRE�GTIOINS., f. "'w <br /> �� e is _ w. <br /> s <br /> 1� PRIMARY & 3 AMERON gO 4 TOP SE4L GAP MORRISON BRgS. 05CU AND AI} <br /> " APTER PHIL-TITE ENTERPRISES #SWF7100. 4 <br /> DUALOY 3000L OR SMITH <br /> RED THREAD FIBERGLASS <br /> SECONDARY VENT 1p" CONDUIT PENEfRAT10N-=S�&,ING--GROMMET.`-AMERIC I,..LINING`-OMPRESSIONF" Gr-OR TE..RI GLASS. (MUST WITHSTAND <br /> \� \�\ � �/fes� 13 O HYDROSTATIC TESTING). <br /> HOLD THIS DIMENSION TO �` 20 --= i PLAN VIEW SHOWS SUGGESTED PIPING <br /> ASSURE (5) GALLON CAPACITY ORIENTATION. IN ELEVATION VIEWo SUMP REDUCER WITH DOUBLE OFFSET PHIL.-ATE M-4933-5RDO. <br /> OF SPILL COLLECTOR �� 21 �� BELOW, SOME PIPING WAS BEEN DELETED1 t <br /> BULKHEAD FITTING AND REDUCING BOOT WITH TEST PORT. WEAVER 111504A-32-0240. <br /> FOR CLARITY 8 <br /> 3 - _____-�' NOTE: <br /> @_;rORIENT ACCESS OPENING IN x 24'°.,FEMALE_x MALE STAINLESS BRA1DFI�EX�__CONNECTOR TITEFLEX 111504A-32-0240. <br /> r s " <br /> 4 MANHOLE OVER SUMP SENSOR OVERFILL FLOAT VALVE, INSTALLED IN AND RETURN <br /> / J--BOX. SUMP SENSOR MUST BE t4 ` <br /> ABLE TO BE EASILY REMOVED <br /> VERTICALLY. t5 rRI?TURN LINE 4"x4"z2'�150 MALLEABL` IRON-EX71?ACT� FITTING WITH PLUG & 2"x1" 150# MALLEABLE IRON REDUCING <br /> O +BUSHING. OPW -44 . <br /> NOTE: 16 EXTRACTOR CAP, MQRRISON OROS. #578. <br /> i <br /> USE SPACERS TO ENSURE MANHOLE <br /> f IS CENTERED OVER WATER TIGHT 17 5, GALLON SPILL_.,BUCKS[.,,,PH#L=TITS #85-100F. <br /> SUMP SHIELD ; �... `4 <br /> PLAN VIEW 18 3" FILL DROP TUBE, OPW 161T-7244. <br /> 4 ffE <br /> ONIVER' -SENOR-„MOf1NTING-KJT,_`VEbDER-ROOT 9330020-012. <br /> 20 UL LISTED LOCKABLE BALL. VALVE TO MATCH PIPE SIZE. <br /> \ / IMPORTANT O 21 PIPE BUSHING 150# MALLEABLE IRON. <br /> MAINTAIN SLOPE AWAY FROM ALL MANWAY <br /> 4P <br /> COVERS 3” IN 6' OR TO EDGE OF SLAB 22 PHIL—TITS VACUUM TEST FITTING. <br /> (WHICHEVER IS CLOSER) <br /> WATERTIGHT SUMP SHIELD <br /> 7 24 17 9 22 16 7 PHIL-TITS SPILL OUGKETT ADAPTOR MF 4X4. <br /> 8 5 23 24 PHIL�-TITS 8" RUBBER CAP WITH BAND CLAMP. <br /> ADAPTER (TYP) #4 i 2" O.C. BOTH WAYS 25 SECONDARY CONTAINMENT TEST FITTING. <br /> O <br /> p p b <br /> 1> <br /> F z 4t> ��: - �� - ~ -= : �- WESTERN FIBERGLASS MATERIAL LIST <br /> Nk <br /> ITEM NUMBER DESCRIPTION <br /> LNNOTE- <br /> m \//� SLOPE SIDES OF TANK /\ PI4531 4" UCOR OF SUMP WALL) <br /> HOLE OR USE SHORING /\`/ P11100 3/4" CO—FLEX PIPE <br /> NP. 23 a FOR ALL TANK EXCAVATIONS „ <br /> " IN ACCORDANCE WITH CAL/OSHA P11101 1 CO—FLEX PIPE <br /> 2 THREADED PVC CAP' / AC8422 PENETRATION B5"x3.5" W/FLANGE <br /> -- HAND--TIGHT ONLY z z SEAL OFF CONSTRUCTION SAFETY ORDERS. <br /> 1* C. a a <br /> P14682UR BOOT REDUCER 5"X3.5" <br /> F o <br /> I <br /> v oLi I 23 (INTERIOR OF SUMP WALL) <br /> L I AC8422 PENETRATION B5"x3.5"F W FLANGE <br /> �, TO LEAK MONITOR/LEVEL GAUGE CONTROL m � I 19 GAUGE PROBE RISER- / <br /> PANEL. (AFTER BUILDING PENETRATION, ( P14682UR BOOT REDUCER 5"x3.5- <br /> 00 <br /> i c i 3/4" CONDUIT MAY BE USED) a I I 4 3 12 AC8491UR REDUCER FITTING 4"xt x1" <br /> Cn <br /> tE ge 10 (TYP.) I <br /> 0 a- 0 O I OUTSIDE_OF BUILDING) <br /> ¢ 3 P14531 4" DUCT <br /> CONCRETE SLAB MUST EXTEND <br /> 12" PAST EXCAVATION z Pf1100 3/4" CO-FLEX PIPE SW♦1 04,6G <br /> PERIMETER ALL AROUND 2 1/2" SCH. 40 SCOTCH <br /> PI11D1 t" CO-FLEX PIPE <br /> COATED BLACK STEEL PIPE - I <br /> ° 1 I AC8479UR REDUCER FITTING 4"x3" REVISIONS / AUTHORIZATIONS <br /> � a <br /> j. <br /> ---� --- -- -�- -- --I INSIDE OF BUILDING <br /> AC8479UR REDUCER F rnlNG 4"xl"x 1" No. REVISE / A0„�IZATIoIS DAVE BY <br /> 14 I o <br /> MASTER DRAWINGS 3/4/03 <br /> I ( I I USE ONLY URETHANE TEST BOOTS Q PER CLIENT INSTRUCTIONS 11/12/03 DM <br /> 794380-208 SENSOR 2 I I ,.1' 1/2" SCH. 40 <br /> (SUMP LOW POINT) UPDATED TO 01/23/04 STANDARDS 2/23/04 DW <br /> I `- BLACK STEEL PIPE I 2 <br /> � <br /> I I I <br /> I ( I I PROPRIETARY SBC INFORMATION <br /> NOT FOR GENERAL USE OR DISCLOSURE OUTSIDE OF SBC <br /> THIS INFORMATION BE <br /> THE LOCAL GOVERNMAENTONLY AGENCY IN ECONNECT ON AUTHORIZED WITH APPLICATION FOR <br /> I I .......I. \ FILTER FABRIC (WHEN REQ'D PERMITS AND AUTHORIZATIONS FOR BUILDINGS, CONSTRUCTION, AND/ OR <br /> WITH UNSTABLE SOIL AND/WITH <br /> CHANGES. <br /> OR HIGH WATER TABLE DRAWINGS PREPARED FOR <br /> I I I I I \\fie <br /> CORPORATE <br /> STRIKE PLATE \/ REAL ESTATE <br /> I LINDER ALLI I I <br /> I OPENINGS <br /> NOTE: <br /> IN CASES WHERE A REFURBISHED TANK ♦ I794390-420 ( 3 2 PRODUCT10 <br /> "L <br /> IS USED, THE ABOVE FILL BOX DETAIL LEAK SENSOR ( I 45• PROBE PROJECT 7mE /� (`� <br /> AND ASSOCIATED NOTES BELOW TAKE ` I I I \ E S C A L V N <br /> c� PRECEDENCE. I <br /> ___- " I _ _ \/\ 1812 COLEY AVENUE <br /> - _ j I <br /> \\\ X` ESCALON, CALIFORNIA <br /> ,DEAOI,W NOT-SHOA FQR CLARITY /✓// <br /> CLLC=ESCLCAl1 UG-0 10 <br /> SLOPE-TANK DOWN TdWARD FILL"END 2": /// SHEET TITLE <br /> MURED OVER LENCrTH DF 4k#1 ' <br /> EAS "TANK ry \\ ' UNDERGROUND FUEL TANK <br /> SUCTION SYSTEM <br /> TANK SECTION SLAB PLAN <br /> 3/4" PEA GRAVEL <br /> EWAGEMENT NUMBM: DATE 09/16/03 SCALE AS NOTED <br /> 1'-0„ \�\ <br /> BER AND BACKFILL CONSULTING ENGINEERS BRAWN BY: DW CHECKED BY TP <br /> TYP. ■ 2880 Sunrise Boulevard SBC AUTHORIZATION: SHEET: 3 OR 8 SHEET'S SHEET NO. <br /> Suite 206 SBC DRAWING <br /> Rancho Cordova. CA 95742 �" <br /> 1 TYPICAL TANK SUCTION SYSTEM SCALE. NONE TAIT & ASSOCIATES, INC. ((916) 635-2444 916) 635-2606 Fax F3 <br />