My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VALPICO
>
550
>
2300 - Underground Storage Tank Program
>
PR0536555
>
COMPLIANCE INFO_2015 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/25/2019 3:04:34 PM
Creation date
11/25/2019 8:30:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015 - 2018
RECORD_ID
PR0536555
PE
2351
FACILITY_ID
FA0020989
FACILITY_NAME
Arco. Am pm 83333
STREET_NUMBER
550
Direction
W
STREET_NAME
VALPICO
STREET_TYPE
Rd
City
Tracy
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
550 W Valpico Rd
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
337
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for Arco. Am pm 83333 as of May 14, 2017. <br /> Open violations from October 26, 2016 inspection <br /> Violation #305 -VPH monitoring of the interstitial spaces of the UST system is not maintained. <br /> -The brine levels in the vent sump were several inches below the top of the sump-the technician added brine at the <br /> time of inspection. Records on site show that brine was added to all UDC sumps on 10/13/16. <br /> -The brine sensors in the UDC interstitials were placed at the bottom of the brine reservoirs, approximately 8 inches <br /> below the liquid levels, and not located to detect a leak at the earliest opportunity. <br /> -The communication inside the fill and STP sumps(6 sumps total)was not tested during today's inspection and <br /> could not be verified functional. <br /> The sensors monitoring the liquid level in the interstitial space shall be maintained so that a breach in the primary or <br /> secondary containment is detected before the hazardous substance is released into the environment. Ensure that <br /> monitoring of the interstitial space is maintained at all times and that all potential leaks are properly addressed. <br /> Immediately schedule for verification testing of the sump interstitial communication (all EHD staff time associated <br /> with this reinspection will be billed at the current hourly rate). If alterations will be made to the sumps to allow for <br /> easier communication testing, they must be done under permit and inspection of the EHD. <br /> Violation #316 -Secondary containment not constructed to prevent water intrusion (after Jul 2003). <br /> Water was found in the 91 STP sump, diesel STP sump, and 87 fill sump. Secondary containment shall be <br /> constructed to prevent any water intrusion into the system by precipitation, infiltration, or surface runoff. The service <br /> technician removed the liquid from the sumps and returned the sensors to their proper location. Immediately <br /> contact a properly licensed, trained, and certified contractor to address the water intrusion into the 91 STP sump, <br /> diesel STP sump, and 87 fill sump under permit and inspection of the EHD. <br /> Page 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.