My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VALPICO
>
550
>
2300 - Underground Storage Tank Program
>
PR0536555
>
COMPLIANCE INFO_2015 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/25/2019 3:04:34 PM
Creation date
11/25/2019 8:30:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015 - 2018
RECORD_ID
PR0536555
PE
2351
FACILITY_ID
FA0020989
FACILITY_NAME
Arco. Am pm 83333
STREET_NUMBER
550
Direction
W
STREET_NAME
VALPICO
STREET_TYPE
Rd
City
Tracy
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
550 W Valpico Rd
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
337
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
eco,,./ <br /> l \ � 111 I t CCOl:lllh COMAIANCC <br /> Spill Bucket Testing Report Form r CU <br /> This form is intended for use by contractors performing annual testing of UST spill containmEnt structures. The completedArrr[qnd <br /> printouts from tests(if applicable), should be provided to the facility owner/operator for submittal to the local regulatory- agency. <br /> 1. FACILITY INFORMATION <br /> Facility Name: ARCO I Date of Testing: 10/26/2016 <br /> Facility Address: 550 W.Valpico Road,Tracy, CA 95376 <br /> Facility Contact: Edgar Rizkalli I Phone: (925)548-7910 <br /> Date Local Agency Was Notified of Testing: 10/12/2016 <br /> Name of Local Agency Inspector(i(present during testing): Stacy Rivera <br /> 2. TESTING CONTRACTOR INFORMATION <br /> Company Name: ECO-CHEK Compliance, Inc. <br /> Technician Conducting Test: Nik Zagorov <br /> Credentials': N CSLB Contractor N ICC Service Tech. N SWRCB Tank Tester ❑ Other(Spec) <br /> License Number(s): 958763 <br /> 3. SPILL BUCKET TESTING INFORMATION <br /> Test Method Used: N Hydrostatic ❑ Vacuum ❑ Other <br /> Test Equipment Used: Tape Measure/Level Change Indicator Equipment Resolution: 1/16"/0.0025 <br /> Identify Spill Bucket(By Tank 1 87-E 2 87-W 391 4 Diesel <br /> Number, Stored Product, etc. <br /> Bucket Installation Type: ❑ Direct Bury ❑ Direct Bury ❑ Direct Bury ❑ Direct Bury <br /> N Contained in Sump N Contained in Sump N Contained in Sump N Contained in Sum <br /> Bucket Diameter: 12 Inches 12 Inches 12 Inches 12 Inches <br /> Bucket Depth: 14 Inches 14 Inches 14 Inches 14 Inches <br /> Wait time between applying 10 Minutes 10 Minutes 10 Minutes 10 Minutes <br /> vacuum/water and start of test: <br /> Test Start Time(TI): 09:55 AM 09:55 AM 09:55 AM 09:55 AM <br /> Initial Reading(RI): 13 5/8 Inches 13 3/4 Inches 15 Inches 14 7/8 Inches <br /> Test End Time(TF): 10:55 AM 10:55 AM 10:55 AM 10:55 AM <br /> Final Reading(RF): 13 5/8 Inches 12 3/4 Inches 15 Inches 14 7/8 Inches <br /> Test Duration(TF—Tj): 60 Minutes 60 Minutes 60 Minutes 60 Minutes <br /> Change in Reading(RF-RI): 0 Inches 1 Inch 0 Inches 0 Inches <br /> Pass/Fail Threshold or 1/16 Inches 1/16 Inches 1/16 Inches 1/16 Inches <br /> Criteria: <br /> Test Result: ® Pass ❑ Fail 1 ❑ Pass ® Fail I ® Pass ❑ Fail ® Pass ❑ Fail <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Tank 87 WEST Spill bucket failed the test and must bereplaced "like for like". <br /> CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br /> I hereby certify that all the information contained in this report is true,accurate, and in full compliance with legal requirements. <br /> Technician's Signature: N O r C)✓ Date: 10/26/2016 <br /> IQ <br /> ' State laws and regulations do not currently require testing to be performed by a qualified contractor.However,local requirements <br /> may be more stringent. <br />
The URL can be used to link to this page
Your browser does not support the video tag.