My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VALPICO
>
550
>
2300 - Underground Storage Tank Program
>
PR0536555
>
COMPLIANCE INFO_2015 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/25/2019 3:04:34 PM
Creation date
11/25/2019 8:30:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015 - 2018
RECORD_ID
PR0536555
PE
2351
FACILITY_ID
FA0020989
FACILITY_NAME
Arco. Am pm 83333
STREET_NUMBER
550
Direction
W
STREET_NAME
VALPICO
STREET_TYPE
Rd
City
Tracy
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
550 W Valpico Rd
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
337
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Arco. Am pm 83333 550 W Valpico Rd, Tracy October 26, 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 304 HSC 25290.1(d) Monitoring system not maintained to detect entry into secondary containment (after Jul 2004). <br /> The 87 STP sump sensor(Veeder-Root 208)failed when tested. The continuous monitoring system shall be <br /> maintained to detect the entry of the liquid or vapor phase of the hazardous substance stored in the primary <br /> containment into the secondary containment and to detect water intrusion into the secondary containment. The <br /> sensor was replaced and retested during the inspection. <br /> This was corrected on site. <br /> This is a minor violation. <br /> 305 HSC 25290.1(e)VPH monitoring of the interstitial spaces of the UST system is not maintained. <br /> -The brine levels in the vent sump were several inches below the top of the sump-the technician added brine at the <br /> time of inspection. Records on site show that brine was added to all UDC sumps on 10/13/16. <br /> -The brine sensors in the UDC interstitials were placed at the bottom of the brine reservoirs, approximately 8 inches <br /> below the liquid levels, and not located to detect a leak at the earliest opportunity. <br /> -The communication inside the fill and STP sumps (6 sumps total)was not tested during today's inspection and could <br /> not be verified functional. <br /> The sensors monitoring the liquid level in the interstitial space shall be maintained so that a breach in the primary or <br /> secondary containment is detected before the hazardous substance is released into the environment. Ensure that <br /> monitoring of the interstitial space is maintained at all times and that all potential leaks are properly addressed. <br /> Immediately schedule for verification testing of the sump interstitial communication (all EHD staff time associated with <br /> this reinspection will be billed at the current hourly rate). If alterations will be made to the sumps to allow for easier <br /> communication testing, they must be done under permit and inspection of the EHD. <br /> This is a minor violation. <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The brine sensors in the UDC interstitials were placed at the bottom of the brine reservoirs, approximately 8 inches <br /> below the liquid levels, and not located to detect a leak at the earliest opportunity. Monitoring equipment shall be <br /> maintained to be able to detect a leak at the earliest possible opportunity. Immediately contact a properly certified <br /> individual to relocate the sensors. Ensure that all monitoring equipment is maintained to detect a leak at the earliest <br /> opportunity. <br /> This is a Class II violation. <br /> 316 HSC 25290.1(c3), 25290.2(c3) Secondary containment not constructed to prevent water intrusion (after Jul 2003). <br /> Water was found in the 91 STP sump, diesel STP sump, and 87 fill sump. Secondary containment shall be <br /> constructed to prevent any water intrusion into the system by precipitation, infiltration, or surface runoff. The service <br /> technician removed the liquid from the sumps and returned the sensors to their proper location. Immediately contact <br /> a properly licensed, trained, and certified contractor to address the water intrusion into the 91 STP sump, diesel STP <br /> sump, and 87 fill sump under permit and inspection of the EHD. <br /> This is a repeat violation, Class II. <br /> Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.