Laserfiche WebLink
San Joaquin County <br /> O.P�U!N' •C Environmental Health Department DIRECTOR <br /> �•' —,C� Donna Heran,REHS <br /> 1868 East Hazelton Avenue <br /> { Stockton, California 95205-6232 PROGRAM COORDINATORS <br /> Robert McClellon,REHS <br /> -�.• Jeff Carruesco,RENS,RDI <br /> c•., P Kasey Foley,REHS <br /> 96;E 6v �� Website: www.sjgov.org/ehd Linda Turkatte,RENS <br /> Phone: (209)468-3420 Rodney Estrada,REHS <br /> Fax: (209) 464-0138 Adrienne Ellsaesser, REHS <br /> October 25, 2013 <br /> Mark Vendeiro <br /> MVP Petroleum Engineering Inc <br /> PO Box 281 <br /> Folsom, CA, 95763 <br /> Re: Arco AMPM SR0068316 <br /> 550 West Valpico Road, Tracy, 95377 <br /> The San Joaquin County Environmental Health Department (EHD) has completed the review of <br /> the application for a permit to repair the possible brine leak into the primary diesel tank on the <br /> underground storage tank (UST) system at the above noted address. The permit has been <br /> approved with the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control <br /> District for any applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval <br /> prior to commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Thuy Tran at (209) 468-8257 to arrange the following inspection appointments <br /> (a 48-hour notice is required for inspection appointments). Please be aware that <br /> inspections for emergency work must be scheduled within five days of permit approval. <br /> a. Diesel Leak detector test: Leak detector must be tested to confirm that the device <br /> can detect a leak of 3 gallons per hour at 10 psi. <br /> b. Primary piping soap test: One hour pneumatic pressure test at 110% of operating <br /> pressure, or 40 psi, whichever is greater. <br /> c. Tank-tightness testing: test per manufacturer's guidelines. Complete and submit the <br /> Truchek Data Log if using Xerex's testing procedures. If there are no manufacturer's <br /> guidelines, test shall be performed using an applicable method specified in an <br /> industry code or engineering standard. <br /> d. Tank Annular Sensor functionality: Functionality of the monitoring system must be <br /> verified to ensure that monitoring has been restored to meet the requirements of Title <br /> 23 California Code of Regulations and the Health & Safety Code. <br /> Please be aware that the facility cannot operate the diesel UST system and receive <br /> fuel in the diesel tank prior to the EHD inspection and approval. <br />