Laserfiche WebLink
TROCNEK <br /> Many tank owners and fuel-system designers choose Xerxes for double-wall tanks.TRUCHEK is an easy,precise and reliable <br /> double-wall fiberglass underground storage tanks because of method for providing continuous leak detection and also for <br /> Xerxes' long history as a leader in underground storage tech- performing a tank-tightness test. <br /> nology.The unique integral-rib design and construction of all <br /> Xerxes tanks make them strong and robust.The fiberglass con- TRUCHEK meets EPA criteria for tank-tightness testing and <br /> struction of these tanks makes them resistant to both internal has received third-party verification from Underwriters <br /> and external rust. Further,more and more customers choose a Laboratories (UL). Like the tanks that Xerxes manufactures, <br /> Xerxes double-wall tank because the two walls of protection TRUCHEK provides a long,successful record of performance. <br /> provide extra security in the unlikely event of a leak. TRUCHEK's performance is based on use in thousands of <br /> tanks in many different types of installations.This proven per- <br /> To enhance that double-wall protection, Xerxes offers the formance is increasingly important as regulations are becoming <br /> option of TRUCHEK,a hydrostatic,tank-monitoring system more strict for the continuous monitoring of double-wall <br /> Tank-Tightness Testing <br /> The TRUCHEK system provides a simple,precise and reliable <br /> method to perform a tank-tightness test. It takes into account Typical Tank-Tightness Test <br /> the impacts of thermal expansion or contraction of the prod- Using TRUCHEK <br /> uct,vapor pockets,tank deflection,evaporation,condensation <br /> and the location of the water table. <br /> Using a simple 10-hour tightness-test procedure while the tank <br /> is not in use,TRUCHEK is capable of detecting a loss of liquid Calibrated Dipstick <br /> in the tank at a rate of 0.05 gallons per hour with a 99%prob- Or Ruler <br /> ability of detection (PD) and a 1% probability of false alarm <br /> (PFA).This meets the strict NFPA 329 criteria. ---Vent in Standpipe <br /> 4-inch Standpipe <br /> A shorter 4-hour test, which allows product dispensing, is (not provided by Xerxes) <br /> capable of detecting a loss of liquid in the tank at a rate of 0.05 <br /> gallons per hour with a 95%probability of detection(PD)and <br /> a 5% probability of false alarm (PFA). This shorter test <br /> exceeds <br /> EPA's criteria for a tank-tightness test stating that a test must Monitoring Fluid <br /> be able to detect a leak rate of 0.1 gallon per hour with a 95% in Standpipe <br /> Reservoir, (during test only) <br /> Features and Benefits <br /> ■ Has third-party verification from Underwriters <br /> Laboratories (UL) <br /> ■ Meets or exceeds EPA and NFPA testing criteria <br /> ■ Can be tested at the time of installation as well as PD and a 5%PFA. <br /> during the lifetime of a tank To conduct a TRUCHEK test, follow the TRUCHEK Tank- <br /> ■ Allows product dispensing during the 4-hour test Tightness Testing Procedure outlined in this brochure and fill <br /> ■ Can be performed on a variety of tank sizes,as in the attached TRUCHEK Data Log form as appropriate for <br /> large as the Xerxes double-wall,30,000-gallon tank the diameter size of the tank to be tested.Keep the completed <br /> form as part of the tank records that may be required by federal, <br /> ■ May provide a less expensive option to periodic tank state and/or local regulations or codes. <br /> tests as a way to meet regulations <br />