550
>
2300 - Underground Storage Tank Program
>
PR0536555
>
COMPLIANCE INFO_2012 - 2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/25/2019 3:01:19 PM
Creation date
11/25/2019 10:41:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2014
RECORD_ID
PR0536555
PE
2351
FACILITY_ID
FA0020989
FACILITY_NAME
Arco. Am pm 83333
STREET_NUMBER
550
Direction
W
STREET_NAME
VALPICO
STREET_TYPE
Rd
City
Tracy
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
550 W Valpico Rd
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
233
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TRUCHEK DATA ILS <br /> Fill out the site location,tank information and test boxes below. Be sure to choose the correct test box according to the diame- <br /> ter of the tank being tested. Follow the test procedures on the other side of this form.A separate test form is needed for every <br /> tank. For additional copies of the form,contact the UST coordinator at the Xerxes manufacturing facility nearest you. (See <br /> back cover for information.) <br /> SITE LOCATION AND TANK INFORMATION <br /> Site Location: Tank Information: <br /> Address: Nominal Gallons: <br /> Diameter: <br /> Phone: Approximate standpipe length: <br /> Contact name: Product type: <br /> Test Date: Person Performing Test: <br /> • • • • • • DOUBLE-WALL <br /> 95% - 5% TEST 99% - 1% TEST <br /> Ia.Start level (inches in standpipe) 1b. Start level(inches in standpipe) <br /> 2a. End level after 4 hours - 2b. End level after 10 hours - <br /> 3. Difference(subtract 2a from la)= 3. Difference(subtract 2b from lb)= <br /> 4. Calibration factor x .20 4. Calibration factor x .20 <br /> 5. Volume change = 5. Volume change = <br /> 6. Test hours - 4 6. Test hours - 10 <br /> 7. Gallons-per-hour loss = 7. Gallons-per-hour loss = <br /> (If 0.05 gallons/hour or less, tank passed.) (If 0.05 gallons/hour or less, tank passed.) <br /> Note: maximum allowable dispensing volume Note: No product dispensing allowed. <br /> during test: <br /> 8-foot-diameter tank- 1,200 gallons maximum <br /> 6-foot-diameter tank- 500 gallons maximum <br /> 4-foot-diameter tank- 300 gallons maximum <br /> 0-FOOT-DIAMETER DOUBLE-WALL <br /> 95% - 5% TEST 99% - 1% TEST <br /> Ia.Start level (inches in standpipe) 1b. Start level (inches in standpipe) <br /> 2a. End level after 6 hours - 2b. End level after 10 hours _ <br /> 3. Difference(subtract 2a from Ia)= 3. Difference(subtract 2b from 1b) _ <br /> 4. Calibration factor x .30 4. Calibration factor x .30 <br /> 5. Volume change = 5. Volume change = <br /> 6. Test hours T 6 6. Test hours _ 10 <br /> 7. Gallons-per-hour loss = 7. Gallons-per-hour loss = <br /> (If 0.05 gallons/hour or less, tank passed.) (If 0.05 gallons/hour or less, tank passed.) <br /> Note: maximum allowable dispensing volume Note: No product dispensing allowed. <br /> during test: <br /> 10-foot-diameter tank-750 gallons maximum <br /> XERXES@ <br /> CORPORATION <br /> 9 eubsldiery o1 ZCL ComposRes Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.