My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012 - 2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VALPICO
>
550
>
2300 - Underground Storage Tank Program
>
PR0536555
>
COMPLIANCE INFO_2012 - 2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/25/2019 3:01:19 PM
Creation date
11/25/2019 10:41:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2014
RECORD_ID
PR0536555
PE
2351
FACILITY_ID
FA0020989
FACILITY_NAME
Arco. Am pm 83333
STREET_NUMBER
550
Direction
W
STREET_NAME
VALPICO
STREET_TYPE
Rd
City
Tracy
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
550 W Valpico Rd
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
233
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Equipment Certification <br /> For Use By All Jurisdictions Within The State of California <br /> Authority Cited: Chapter 6.7,Health and Safety Code; Chapter 16,Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification cr report must be <br /> prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided <br /> to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST system <br /> within 30 days of test date. <br /> A. General Information <br /> Facility Name: Diamond Petroleum 550 Bldg,No.: <br /> Site Address: 550 W.Valpico Rd. City: Tracy, CA Zip: 95376- <br /> Facility Contact Person: Manager Contact Phone No.: (925)000-0000 <br /> Make/Model of Monitoring System: VR ILS-350 Date of Testing/Servicing: 1214/12 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to Indicate specific equipment inspected/serviced: <br /> Tank ID:01-Regu Tank ID: 02-Prem <br /> ® In-Tank Gauging Probe. Model: VR x47390-109 0 In-Tank Gauging Probe, Model: VR 847390-109 <br /> Dil Annular Space or Vault Sensor. Model: VR 794380.303 ® Annular Space or Vault Sensor. Model: VR 794380.303 <br /> ® Piping Sump\Trench Sensor(s). Model: VR 794380.208 ® Piping Sump\Trench Sensor(s). !Model: VR 794380.208 <br /> IR Fill Sump Sensor(s). Model: VR 794380-208 ® Fill Sump Sensor(s). Model: VR 794380-208 <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Lute Leak Detector. '.Model: <br /> ® Electronic Late Leak Detector. Model: VR Sorioa 8484 ® Electronic Line Leak Detector. Model: VR dories 8484 <br /> ❑ Tank Overfill\High-Level Sensor. Model: ❑ Tank Overfill\High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank IIS: 03-Diesel Tank ID: <br /> ® In-Tank Gauging Probe. Model: VR 847390-109 ❑ In-Tank Gauging Probe. Model: <br /> ® annular Space or Vault Sensor. Model: VR 794380303 ❑ Annular Space or Vault Sensor. Model: <br /> Z Piping Sump\Trench Sensor(s). Model: VR 794380-208 ❑ Piping Sump\Trench Sensor(s). Model: <br /> N Fill Sump Sensor(s). Model: VR 794380-208 ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ® Electronic Line beak Detector. Model: VR Soria*8484 ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill\High-Level Sensor. Model: ❑ Tank Overfill\High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment typo and model in Section E on Page 2). <br /> Disppenser El)- 01.02 Dispenser W- 03-04 <br /> ® Dispenser Containment Sensor(s). Model: VR 794380.208 ® Dispenser Containment Sensor(s). Model: VR 784380-208 <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Disgw-n.ser Containment Float(s)and Chain(s). <br /> Dispenser ID: 05.06 Dispenser ID: 07-08 <br /> ® Dispenser Containment Sensor(s). Model: VR 794380.208 ® Dispenser Containment Sensor(s). Model: VR 794380.208 <br /> N Shear Valve(s). ® Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID• Q9-10Dispenser D. 11-12 <br /> ® Dispenser Contairtment Sensor(s). Model: YR 794390.208 ® Dispenser Containment Sensor(s). Model: VR 794380-208 <br /> ® Shear Valve(s). N Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility <br /> C. Certification- I certify that the equipment Identified In this document was inspected/serviced in accordance with the <br /> manufacturer's guidelines. Attached to this Certification is information(e.g.manufactures'checklists)necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equipment For any equipment capable of generating such <br /> reports,I have also attached a copy of the; (cheek all that apply); ® System set-up IN Alarm history report <br /> Technician Name(print): M ke Briggs Signature: <br /> Mfg.Cert.#.: 838235 ICC# 8033115-UT License.No.: 485184 <br /> Testing Company Name: Service Station Systems Phone No.: (408)971-2445 <br /> Testing Company Address: 680 Quinn Ave., San Jose, CA 95112 Date of Testing/Servicing: 12/4112 <br />
The URL can be used to link to this page
Your browser does not support the video tag.