Laserfiche WebLink
San Joaquin County <br /> !o.... ........c <br /> --• \ Environmental Health Department DIRECTOR <br /> Donna Heran,REHS <br /> 1868 E. Hazelton Avenue <br /> t ) Stockton, California 9520562.32 PROGRAM COORDINATORS <br /> ' Robert McClellon,REHS <br /> Jeff Carruesco,REHS, <br /> n;F o R?` Website: ww9 .orKasey Fol ey,R EH S <br /> Phone: (20 )468-3420 Linda Turkatte,REH <br /> S <br /> RMMWD <br /> Fax: (209)464-3433 <br /> A AUG 04 <br /> APPLICATION FOR UNDERGROUND STORAGE TANK <br /> RETROFIT OR PIPING REPAIR PERMIT EiIMEAlTi4lfiALTH <br /> P'PERMIT7,gFRVICFc <br /> [] 1. Submit all information in triplicate. Answer all questions, leaving no blanks. One copy will be returned to the <br /> applicant with comments. <br /> [] 2. Include a detailed site map on a separate sheet of paper showing all work to be done. Include the location of <br /> the tanks(s),piping,all tank-related appurtenances,streets,adjacent properties(north toward the top of the page), <br /> nearby septic tanks, leachfields, water wells, buildings, underground public utility lines (including water, sanitary <br /> sewer and storm sewer), and distance of piping from tank to dispensers. If underground utilities are not included <br /> on the site map,you must state in writing that USA Dig will be contacted prior to excavation activities. <br /> [] 3. Complete pages 3-61 "APPLICATION FOR UNDERGROUND STORAGE TANK RETROFIT OR PIPING <br /> REPAIR PERMIT'. NOTE: If sampling is required, sampling firm shall be an independent third party from the <br /> contractor performing the work. <br /> [] 4. Complete page 7, "Authorization to Release". This form must be signed and dated by the <br /> OWNER/OPERATOR ofthe facility. <br /> [] 5.Submit a completed"Service Request"form and"Underground Storage Tank Program Fee Worksheet'. <br /> [] 6. If performing any excavation activities, and the facility is located outside of the city limits, submit a "Backfill <br /> Excavation Certificate" as required by the San Joaquin County Building Department. If a 'Backfill Excavation <br /> Certificate" is required by any incorporated areas (cities), submit to the appropriate City Building Departments, <br /> pursuant to the Uniform Building Code STD 70-11. <br /> [] 7.The maximum review time for Plan Review is 15 working days from receipt of the adequately completed plan. If <br /> gross deficiencies are identified, an addendum will be required with a $125.00 per hour fee and the review will <br /> begin on the date of resubmittal. <br /> [] 8.Advance inspection notice of at least 48 hours is required by the Environmental Health <br /> Department(EHD). <br /> [] 9. Contractor to Provide: Combustible/Flammable gas detector (to verify the Lower Explosive Limit (LEL) <br /> atmosphere and oxygen level),adequate number(s)and appropriate type(s)of fire extinguisher(s), and barriers to <br /> secure the area as necessary to minimize traffic and pedestrian interference. It shall be the project manager's <br /> responsibility for compliance with all health & safety regulations and requirements, including confined space <br /> requirements, which shall be strictly adhered to at all times during the course of the underground storage tank <br /> (UST)activities. <br /> [] 10.The EHD permit shall be on site during all UST permit-related activities. <br /> [] 11.Any changes in this document shall be approved by the EHD priorto initiating work. All changes to any work <br /> must be described in detail on pages 3&4 and be shown on the detailed site map. <br /> 1 <br />