My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
440
>
2300 - Underground Storage Tank Program
>
PR0231055
>
COMPLIANCE INFO_2012 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/27/2019 3:47:04 PM
Creation date
11/26/2019 9:20:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2018
RECORD_ID
PR0231055
PE
2361
FACILITY_ID
FA0002321
FACILITY_NAME
Delta arco
STREET_NUMBER
440
Direction
W
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
16503003
CURRENT_STATUS
01
SITE_LOCATION
440 W DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
364
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3,Title 23,California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system Co. <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. M o C-) <br /> A. General Information —4 m N <br /> Facility Name: DELTA ARCO Bldg.No.: W <br /> = N <br /> Site Address: 440 W CHARTER WAY City: STOCKTON Zip: 95206 <br /> Facility Contact Person: MAJOR Contact Phone No.: (209)465-2487 <br /> Make/Model of Monitoring System: VEEDER ROOT 350 Date of Testing/Servicing: 08-30-17 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br /> TanklD: 87 TanklD: 91 <br /> E In-Tank Gauging Probe. Model: MAG 1 E In-Tank Gauging Probe. Model: MAG 1 <br /> E Annular Space or Vault Sensor. Model: 420 E Annular Space or Vault Sensor. Model: 420 <br /> E Piping Sump/Trench Sensor(s). Model: 208 E Piping Sump/Trench Sensor(s). Model: 208 <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> E Mechanical Line Leak Detector. Model: 99 LD 2000 E Mechanical Line Leak Detector. Model: 99 LD 2000 <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> E Tank Overfill/High-Level Sensor. Model: FLAPPER E Tank Overfill/High-Level Sensor. Model: FLAPPER <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> TanklD: TanklD: <br /> ❑ In-Tank Gauging Probe. Model: ❑ In-Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: ❑ Annular Space or Vault Sensor. Model: <br /> ❑ Piping Sump/Trench Sensor(s). Model: ❑ Piping Sump/Trench Sensor(s). Model: <br /> �I ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> r❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 3-4 <br /> E Dispenser Containment Sensor(s). Model: 208 E Dispenser Containment Sensor(s). Model: 208 <br /> E Shear Valve(s). E Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5-6 Dispenser ID: 7-8 <br /> E Dispenser Containment Sensor(s). Model: 208 E Dispenser Containment Sensor(s). Model: 208 <br /> E Shear Valve(s). E Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9-10 DispenserlD: 11-12 <br /> E Dispenser Containment Sensor(s). Model: 208 E Dispenser Containment Sensor(s). Model: 208 <br /> E Shear Valve(s). E Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): E System set-up E Alarm history report <br /> Technician Name(print): FELIX RAMIREZ Signature: <br /> Certification No.: 5273934-UT License No: 08-1740 <br /> Testing Company Name: AFFORDA-TEST Phone No. _(2744-0112 <br /> Testing Company Address: 416 2n0 STREET GALT,CA 95632 Date of Testing/Servicing: 08-30-17 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br /> P90-231OSS <br /> F A 000.2 3:,� <br />
The URL can be used to link to this page
Your browser does not support the video tag.