My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE_FILE 2
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6131
>
3500 - Local Oversight Program
>
PR0545003
>
SITE INFORMATION AND CORRESPONDENCE_FILE 2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/27/2019 11:04:58 AM
Creation date
11/27/2019 10:58:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE INFORMATION AND CORRESPONDENCE
FileName_PostFix
FILE 2
RECORD_ID
PR0545003
PE
3526
FACILITY_ID
FA0002324
FACILITY_NAME
Pacific Service Station
STREET_NUMBER
6131
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
09746418
CURRENT_STATUS
02
SITE_LOCATION
6131 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
`7-1996 1 : 1 3PM FROM P_ 5 <br /> en viros,., <br /> October 10, 1996 <br /> Ms. Mary Meays <br /> San Joaquin County Public Health Services <br /> P.O. Box 388 <br /> Stockton, California 95201-0388 <br /> RE: Shell Service Station <br /> 6131 Pacific Avenue <br /> Stockton, California <br /> WIC 204-7525-0104 <br /> Dear Ms. Meays: <br /> This letter is prepared in response to San Joaquin County Public Health Services <br /> (SJCPHS) correspondences dated May 9, 1996 and August 15, 1996. These <br /> correspondences address several issues. Responses to these items have been prepared <br /> individually. <br /> Field Notes for February 28 and May 16, 1996 Sampling Events <br /> As requested, the field notes for these events are enclosed. Additionally, field notes for <br /> future sampling events within SJCPHS's jurisdiction will be included with the quarterly <br /> monitoring events. <br /> Depth to Water Measurements <br /> Depth to water is measured and recorded on the field data sheets prior to purging activities. <br /> Shell's protocol for ground water sampling calls for wells to be recharged to 80% of their <br /> static levels after purging,prior to sampling. This is consistent with GUFF Manual and <br /> SJCPHS guidelines. Typically, wells in this area do not de-water and recharge sufficiently <br /> to meet this sampling protocol immediately after purging. In response to your request,we <br /> propose to measure and record the depth to water immediately following purging activities <br /> during fourth quarter sampling events. Any wells which do not achieve adequate recharge <br /> immediately will be noted and checked again during subsequent sampling events. For <br /> wells which do not pose a problem,collection and recording of post-purge water levels will <br /> be a one-time event. <br /> Collection of Ground Water Samples from Well VE-2 <br /> As requested,ground water samples were collected from this well during the third quarter <br /> sampling event. Results will be reported in the third quarter report,along with an <br /> evaluation of the monitoring capabilities of the site. <br /> Comments on May 1, 1996 Work Plan <br /> Enr/ron. Inc. 310 PerklnS Street Scnpm,0.(;,,Idornr0 Tvl)0]/9!5.4850 <br /> PA 50n Z59 ru W, M.6619 <br />
The URL can be used to link to this page
Your browser does not support the video tag.