My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0006799
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6131
>
3500 - Local Oversight Program
>
PR0545003
>
ARCHIVED REPORTS_XR0006799
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/27/2019 11:42:41 AM
Creation date
11/27/2019 11:05:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0006799
RECORD_ID
PR0545003
PE
3526
FACILITY_ID
FA0002324
FACILITY_NAME
Pacific Service Station
STREET_NUMBER
6131
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
09746418
CURRENT_STATUS
02
SITE_LOCATION
6131 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
885 Jarvis Drive <br /> Sequoia Morgan HIII 77 95037 <br /> ` (408)776-9600 <br /> FAX(408)1782 63081, <br /> Analytical <br /> 5equoiaiabscorn <br /> Blaine Tech Services(Shell) Project 6131 Pacific Ave " <br /> 1680 Rogers Avenue Project Number 6131 Pacific Ave I Stockton Reported <br /> San Jose CA,95112 Project Manager Flick Sudano 06/06/00 11 46 <br /> Notes and Definitions <br /> A-01 This sample did not contain MTBE however there appears to be 2-methyl-pentane present <br /> A-03 There was not a good library match for MTBE for this sample due to coelution with 2-methyl-pentane,however the results were <br /> reported on-visual confirmation of the quantitation ions for MTBE <br /> H-02 This sample was analyzed outside of EPA recommended hold time <br /> P-01 Chromatogram Pattern Gasoline C6-C12 <br /> Q-01 The spike recovery for this QC sample is outside of established control limits Review of associated batch QC indicates the <br /> recovery for this analyte does not represent an out-of-control condition for the batch <br /> Q-07 The RPD value for this QC sample is above the established control limit Review of associated QC indicates the high RPD does <br /> not represent an out-of-control condition for the batch <br /> S-04 The surrogate recovery for this sample is outside of established control limits due to a sample matrix effect <br /> DET Analyte DETECTED - <br /> ND Analyte NOT DETECTED at or above the reporting limit <br /> NR Not Reported <br /> dry Sample results reported on a dry weight basis <br /> RPD Relative Percent Difference <br /> n <br /> Sequoia Analytical-Morgan Hill The results in this report apply to the samples analyzed in accordance with the ch <br /> custody document This analytical report must be reproduced in its enti <br /> Page 11 of ll <br />
The URL can be used to link to this page
Your browser does not support the video tag.