Laserfiche WebLink
e <br /> F Client Name Blaine Tech Services Date 05/26/1995 <br /> r • Client Acct 1821 SLAP Cert 1386 <br /> ® NET Sob No 95 01994 Page e <br /> Ref Shell 6131 Pacific Avenue Stockton, CA/950516-E2 <br /> CONTINUING CALIBRATION VERMCATION STANDARD REPORT <br /> CCV CCV <br /> CCV Standard Standard Run <br /> Standard Amount Amount Date Analyst Hatch <br /> Parameter % Recovery Found Exsected Unite Anal ed Initials Number <br /> METHOD 5030/8015-M (Shell) <br /> 98 0 0 49 0 SU mg/L 08/23/1995 caf 2858 <br /> Purgeable TPH <br /> 05/23/1995 caf 2858 <br /> Benzene 99 6 4 98 5 00 ug/L <br /> Toluene 89 2 4 46 5 00 ug/L 05/23/1995 caf 2858 <br /> Ethylbenzene 88 0 4 40 5 00 ug/L 05/23/1995 caf 2858 <br /> Xylenes (Tatal) 98 7 14 8 15 0 ug/L 05/23/1995 caf 2858 <br /> Bromofluorobenzene (SURR) 99 0 99 100 t Rec 05/23/1995 caf 2858 <br /> METHOD 5030/8015-M (Shell) <br /> Purgeable TPH 100 0 0 50 0 50 mg/L 05/24/1995 sal 2862 <br /> Benzene 99 2 4 96 5 00 ug/L 05/24/199S sal 2862 <br /> Toluene 99 8 4 99 5 00 ug/L 05/24/1995 aal 2862 <br /> Ethylbenzene 93 6 4 68 5 00 ug/L 05/24/1995 aal 2862 <br /> Xylenes ITotall 102 0 15 3 15 0 ug/L 05/24/1995 aal 2862 <br /> Bromofluorobenzene (SURR) 96 0 96 100 t Rec 05/24/1995 aal 2862 <br />• <br /> 0 NOTE Results apply only to the samples lanalyzed Re roductsoa of this report is permitted only in its ents.rety <br /> yz p <br />