Laserfiche WebLink
' MOBILE CHEM LABS INC. <br /> 5011 Blum Road, Suite 1 • Martinez, CA 94553 <br />' Phone (510 372-3700 • Fax (510) 372.6955 <br />' 14261012510 <br /> WHF Environmental Consultants, Inc. <br /> 1121 Oakdale Rd. <br />' Modesto, CA 95355 Date Sampled: 03-22-93 <br /> Attn: Steve Furnas Date Received: 03-22-93 <br /> Project Manager Date Analyzed: 03-22-93 <br /> Sample Number Sample Description <br /> ------------ ------------------ <br /> i v033043 Union Ice <br /> 1320 W. Weber <br /> Stockton, CA <br />' W-1 WATER <br /> ANALYSIS <br /> Detection Sample <br /> Limit Results <br /> --------- -------- <br /> ppb ppb <br /> Total Petroleum Hydrocarbons 50 <50 <br /> as Gasoline <br /> Benzene 0 .5 <0 .5 <br /> Toluene 0 .5 <0 .5 <br /> Xylenes 0 .5 <0 .5 <br /> IEthylbenzene 0 .5 <0 .5 <br /> QA/QC: Spike Recovery is 81% <br /> Duplicate Deviation is 2 .2% <br /> Note: Analysis was performed using EPA methods 5030 and TPH <br /> LUFT with method 602 used for BTX distinction. <br /> (Ppb) = (µg/L) <br /> MOBILE CHEM LABS <br /> Ronald G. Evans <br /> Lab Director <br /> I <br />