Laserfiche WebLink
Intertek Testing Services <br /> Environmental Laboratories <br /> 1 ' <br /> ' DATE RECEIVED 8-MAY-1997 REPORT NUMBER D97-5618-1. <br /> REPORT DATE 19-MAY-1997 <br /> ' <br /> SAMPLE SUBMITTED BY ITS/San Jose <br /> ' ADDRESS 1961 Concourse Dr Ste E <br /> San Jose, CA 95131 <br /> ATTENTION Todd Geringer <br /> SAMPLE MATRIX Water <br /> ID MARKS CT-1 <br /> 97050382 <br /> PROJECT 544 299600 <br />' DATE SAMPLED 6-MAY-1997 <br /> ANALYSIS METHOD EPA 8021 Mod /1 <br /> ANALYZED BY JCH <br /> ANALYZED ON 13-MAY-1997 <br />' DILUTION FACTOR 1 <br /> METHOD FACTOR 10 <br /> QC BATCH NO 35-051397 <br /> VOLATILE ORGANIC COMPOUNDS <br /> TEST REQUESTED DETECTION LIMIT RESULTS <br />' Benzene 2 0 gg/L < 2 0 kg/L <br /> Ethylbenzene 2 0 kg/L < 2 0 kg/L <br />' Toluene 2 0 ug/L < 2 0 ug/L <br /> 1,2,4-Trimethylbenzene 2 0 g9/L < 2 0 ug/L <br />' 1,3,5-Trimethylbenzene 2 0 ug/L < 2 0 ug/L <br /> o-Xylene 2 0 µg/L. < 2 0 ug/L <br />' m,p-Xylene 2 0 µg/L < 2 0 {tg/L <br /> QUALITY CONTROL DATA <br />' SURROGATE COMPOUND SPIKE RECOVERED <br /> 1-Chloro-3-fluorobenzene (PID) 96 B Y <br /> i <br />' Intertek Testing Services NA Inc <br /> 1089 East Collins Boulevard Richardson, TX 75081 <br /> Telephone (972) 238-5591 Fax (972) 238-5592 <br />