MEMORANDUM <br />■ ■' <br />RECEIVED ME <br />OCT 0 2 2019 <br />ENVIRONMEN FAL HEALTH <br />To: Linda Turkatte, REHS PERMIT/SERVICES <br />From: Paul Schneider, P.E. <br />Date: 10/1/2019 <br />SIEGFRIED <br />Re: Response to Plan Check Comments and Alternate Nitrate Loading Analysis Holly <br />Commerce Center Buildings E&E <br />I. Introduction <br />Siegfried is in receipt of the memorandum prepared by Norman Hantzsche, P.E. or Questa Engineering <br />Corporation dated August 15, 2019. In addition, we have been provided the attached "Attachment 1; <br />Recommended Alternate Nitrate Loading Analysis for Heavily Developed/Impervious Site Conditions" It is <br />further understood that there is an overriding regarding the potential that the site could change from dry <br />warehouse to some other more intense use. The following sections are intended to augment the revised <br />plans and serve as our response to the comments. <br />II. Sewer Collection System Design <br />The plan review comments indicated that there was a concern regarding the gravity collection system. <br />The system design was a cost driven decision and a closer analysis was performed to compare the <br />gravity system to a force main system that alleviates the concerns raised in the comments. Due to <br />favorable results and the concerns raised the design has been revised to a force main system that is not <br />as deep and out of the groundwater. Gravity structures have also been removed. Lastly the filter bed rock <br />depth has been corrected as noted. <br />III. Future Growth and Monitoring Plan <br />As requested, the plans have been altered to include a flow monitor and sensor on the post septic tank lift <br />station that lifts the effluent into the leach field. The project owner has volunteered to enter into the <br />County's monitoring program and will report the waste flows as required. Please see note added to detail <br />2 on sheet C7.3. <br />To address the building use, change potential Siegfried has prepared and attached an exhibit that utilizes <br />the architectural occupancy rates on the current plans and designates a contingency area for leach fields. <br />Please note that the areas are currently shown to be in the loading docks because if the building use <br />were to change to office and demand this large a septic system the loading docks would no longer be <br />necessary, and the truck courts would be converted to auto parking. <br />IV. Alternate Nitrate Loading Analysis <br />It is understood that there is concern over the impact of large amounts of impervious area on the <br />historical Hantzsche-Finnemore equation and an alternate method was requested in the form of <br />Stockton <br />3428 Brookside Rd. <br />Stockton, CA 95219 <br />t: 209.943.2021 <br />San Jose <br />111 N. Market St., #300 <br />San Jose, CA 95113 <br />t: 408.754.2021 <br />Sacramento <br />900 Howe Ave., 4200 <br />Sacramento, CA 95825 <br />t: 916.520.2777 <br />Modesto <br />100 Sycamore Ave, #100 <br />Modesto, CA 95354 <br />t: 209.762.3580 <br />F:\17projects\17017 Holly Sugar Ind ustrial\Civil\Septic Sizing - Prelim\17017 Holly Commerce Center E&E Nitrate Loading Memo <br />Ver 1.docx <br />