In order to avoid cross-contamination of wells during the To minimize the potential for cross-contamination between <br /> liquid-level measurement process,wells are measured in the air samples,the polyethylene tubing,if not sample <br /> order of"clean"to"dirty"(where such information is dedicated,is thoroughly cleaned and rinsed. <br /> available). In addition,all measurement equipment is <br /> cleaned with solution and thoroughly rinsed with deionized Vapor samples are subject to very limited holding times, <br /> water before use,between measurements in respective typically 48 hours. Thus,care must taken to avoid delays in <br /> wells,and at the completion of the day's use. submittal of vapor samples to the laboratory. In the event <br /> the vapor samples cannot be submitted to the analytical <br /> laboratory on the same day they are collected,they are to be <br /> SOP-10 temporarily stored in the dry,non-refrigerated,packed cooler <br /> SOIL VAPOR SAMPLING:"TEDLAR"BAG SAMPLING until the very first opportunity for submittal well within the <br /> TECHNIQUE/REMEDIATION SYSTEM SAMPLING required holding time,taking into account the time needed <br /> for shipment to and receipt by the laboratory. <br /> Prior to vapor sampling,the vacuum system must reach a <br /> stabilized air flow(cubic feet per minute)for approximately <br /> 15 minutes. Prior to the actual collection of the vapor SOP-11 <br /> sample,the following data is recorded:air flow,temperature, VAPOR SAMPLING:SUMA CANISTER SAMPLING <br /> and pressure at collection ports and gauges. TECHNIQUE <br /> The sampling equipment consists of a TedlarTm bag Prior to vapor sampling,the vacuum system must reach a <br /> (available in 1,3,5,and 10 liter sizes),a diaphragm pump, stabilized air flow(cubic feet per minute)for approximately <br /> and 3/16-inch-diameter polyethylene tubing(approximately 1 15 minutes. Prior to the actual collection of the vapor <br /> foot long).The TedlarTm bag should be fitted with an integral sample,the following data is recorded:air flow,temperature, <br /> valve for filling and sealing the bag after sampling.The and pressure at collection ports and gauges. <br /> diaphragm pump inlet and outlet are fitted with 3/16-inch <br /> hose barbs for attaching the sample tubing.Prior to vapor The sampling equipment consists of a sterilized,gas-tight, <br /> sampling,the soil vapor source(vapor screen,vapor "Suma"stainless steel canister(available in one and six liter <br /> extraction well or manifold,etc.)must be isolated for volumes),flow meter(if required,obtained and calibrated by <br /> sampling.A sample label with the sample number and date the laboratory)and 1/4-inch-diameter polyethylene tubing <br /> and time of sample collection is prepared and placed on the approximately 2 feet in length. <br /> TedlarTA°bag. <br /> The sampling ports are brass connections fitted with silicone <br /> If the sample is being collected from an operating vapor septa and threaded into a tapped hole in the system piping. <br /> extraction system,the target vapor manifolds must be set up The sampling procedure requires one end of the tubing to be <br /> with sample ports that can be isolated without interrupting slipped over the sampling port and the other end over the <br /> system operation. Prior to the actual collection of the vapor canister nozzle or flow meter(if required)to acquire an air- <br /> sample,source data is recorded:air flow,temperature,and tight connection.The valve should be opened at this time <br /> pressure;or,well identification number and depth interval of and the initial pressure should then be recorded to verify that <br /> screen. the Suma canister is under vacuum. The Suma canister is <br /> allowed to collect the soil vapor sample at a predetermined <br /> Typical sampling ports consist of a 1/4—inch ball valve fitted duration. After the sample has been collected record the <br /> with a 3/16-inch hose barb to form a slip stream from the final vacuum reading(approximately five pounds per square <br /> sample source. inch gauge(psig))to ensure that the flow meter was working <br /> properly,if applicable. Immediately following the sample <br /> The sampling procedure requires one end of the tubing be collection,complete sampling information is recorded on the <br /> slipped over the sample port hose barb and the other end label on the air sampling canister(e.g.,sample ID,date, <br /> over the diaphragm pump inlet hose barb to form an air-tight time, location,and temperature). The sample is placed in a <br /> connection. The sampling pump is then started and the non-refrigerated,dry cooler with sufficient packing to ensure <br /> pump is purged for one minute with the vapor to be sampled. against damage during transport. Cooling samples will <br /> cause condensation of any moisture within the air sample, <br /> Following purging,the discharge of the pump is then thereby distorting laboratory analysis. <br /> connected to the'Tedlar"bag using a section of 3/16-inch <br /> tubing.The pump is restarted and the bag is opened and Suma canister samples are subject to hold times of typically <br /> allowed to fill to approximately 3/4 of its capacity. Caution 30 days and with some compounds a more rigid hold time of <br /> should be taken not to overfill the sampling bag. The sample 14 days is required. <br /> is placed in a non-refrigerated dry cooler with sufficient <br /> packing to prevent damage during transport. Cooling <br /> samples will cause condensation of moisture within the SOP-12 <br /> sample,thereby distorting the laboratory analysis. SOIL VAPOR SAMPLING:SYRINGE SAMPLING <br /> TECHNIQUE <br /> For quality control purposes,a duplicate vapor sample <br /> should be collected from each sampling port. This sample is Prior to vapor sampling,the vacuum system must reach a <br /> then put on hold at the laboratory pending initial analysis. To stabilized air flow(cubic feet per minute)for approximately <br /> ensure quality control and minimize the potential for cross- 15 minutes. Prior to the actual collection of the vapor <br /> contamination prior to and during sampling,the diaphragm sample,the following data is recorded:air flow,temperature, <br /> pump is thoroughly purged for approximately five minutes and pressure at collection ports and gauges. <br /> with nitrogen or clean air(i.e.,compressed clean air). A <br /> "blank"sample of the discharged air is captured in a'Tedlar" The sampling equipment consists of a clean,100cc,gas- <br /> bag at the end of the purging procedure and may be tight syringe and silicone septa. <br /> analyzed to ensure the purging was effective. <br />