<br />     			SOP _ q    							When practical,the groundwater sample should be collected
<br />    			SArII PLE IDENTIFICATION AND CRAIN-  	when the water level in the well recovers to at least so percent
<br /> I`   			OF-CUSTODY PROCEDURES   			aNtsStatic ievel,
<br />      												The sampling equipment consists of either a"Yellen"bailer,
<br />    			Sample identification and chain-ef-custody procedures ensure   	PVC bailer,or stainless steel bladder pump with a-Teflon"
<br /> '   			sample integrity as well as document sample possession from   	bladder. If the sampling system is dedicated to the well,then
<br /> {  			the time of collection to ultimate disposal. Each sample  		the bailer is usually"Teflan,"but the bladder pump is PVC with
<br />    			container submitted for analysis is labeled to Identify the job,     	a pclyprepytene bladder. In general and depending on the
<br />    			number, date, time of sample collection,a sample number       	intended laboratory analysis,40-milliliter glass,volatile organic
<br /> {   			unique to the sample,any in-field measurements made,  		analysis(VCA)vials,with-Teflon'septa,are used as sample
<br />    			sampling methadalagy,names)al an-site personnel,and any.   	containers.
<br />    			other pertinent field observations also retarded an the field
<br />    			excavadcn ar baring leg.						S a P -.]2
<br /> I.   												MEASURING LIQUID LEVELS USING
<br /> E  			Chain-0f-4--ustody farms are used to record passession of the    	WATER LEVEL METER.OR INTERFACE
<br />    			sample from time of collectan to arrival at the laboratory, 		PROSE
<br />    			During shipment,the person with custody of the samples will  .
<br />    			relinquish them to the next person by signing the chain-af-       	Field equipment used for liquid-levet gauging typically includes
<br />    			custody form(s)and noting the date and time. The sample-      	the measuring instrument(water-level meter or interface probe)
<br />   			contra[officer at the laboratory will verify sample Integrity,		and product bader(s)..The field kit also includes cleaning
<br />   			correct preservation,confirm collection in the proper     		supplies(buckets,solution,spray battles,and deianized water)
<br /> +  			container(s),and ensure adequate volume for analysis,  		to be used in cleaning the equipment between wells.
<br />   			If these conditions are met,the samples will be assigned 		Prior to measurement,the instrument tip is lowered into the well
<br />   			unique laboratory lag numbers far identification throughout       	until it touches bottom. Using the previously established top-0f-
<br />   			analysis and reporting. The lag numbers will be retarded on     	casing or tap-al-box(i.e.,wellhead vault)paint,the probe card .
<br />   			the chain-0f-custody farms and in the legai[y-required lag book   	(or halyard)is marked and a measuring tape(graduated in .		I
<br />   			maintained in the laboratory. The sample description,date       	hundredths of a foot)is used to determine the distance
<br />   			received,client's name,and any ether relevant information will    	between the probe end and the marking an the card- This
<br /> { 			also be retarded,       						measurement is then recorded on the liquid4evei data sheet as
<br />    												the"Measured Total Depth"of the well.
<br />    												When necessary in using the interface probe to measure liquid
<br />   			LABORATORY ANALYTICAL QUALrrY     	levels,the probe is first electdcaltygrounded to either the metal
<br /> j.
<br />   			AS-SURANCE AND CONTROL  			stave pipe or another metal abject nearby. When no ground is ,
<br />    												available,reproducible measurements can be obtained by
<br />   			In addition to routine instrument calibration,replicates,spikes,   	clipping the ground lead to the handle of the Interface probe
<br />   			blanks,spiked blanks,and certified reference materials are      	case.
<br />  			routinely analyzed at method-specific frequencies to manitor     	The probe tip is then lowered into the well and submerged In
<br /> + 			precision and bias. Additional campanents of the laboratory     	the ground,.rater. An ascillating(beeping)tone indicates the
<br />  			Quality AssuranceJQuatity Control program include: '
<br /> i  												probe is in water, The probe is slowly raised until either the
<br /> toscillating-tone ceases or becomes a steady tone. In either
<br />  			1. 	Participation in state and federal laboratory    		case,this is the depth-toarrater(DTW)indicaken and the DTW      	'
<br />     				accreditation/certifica@an programs;
<br />    												measurement is made accordingly. The steady tone indicates
<br />  			2 	Participation in bath U.S. EPA Perfarmance   		floating liquid hydrocarbons(FLH). in this case,the probe Is
<br />     				Evaluation studies(WS and WP studies)and Inter-   	slaw&/raised until the steady tone ceases. This is the depth-ta-
<br />     				laboratory performance evaluation programs;  		product(OTP)Indication and the DTP measurement Is made
<br />   												accardingly.
<br /> `			3, 	Standard operating procedures describing routine
<br />     				and periodic instrument maintenance; 			The process of lowering and raising the probe must be
<br />   												repeated several times to ensure accurate measurements. The
<br />  			4. 	'nut-0f Control"!Corrective Action documentation      	DTW and OTP measurements are retarded an the liquid-level
<br />    				procedures;and,    I 					data sheet-.When FLH are indicated by the probe's response,
<br /> # 												a product bailer is lowered partially through the FLH-water
<br /> 			5- 	Mutti-{evei review of raw data and client reports.       	Interface to confirm the FLH an the water surface and as,
<br />   												further indication of the FLH thickness,particularly in cases
<br /> i       		SO p - 7    							where the FLH layer is quite thin, This measurement Is
<br /> 			GROUNDWATER PURGING AND      		jrecorded an the data sheet as-FLH thickness."
<br />       																					t
<br /> 			SAMPLING
<br />   												In order to avoid crass-cantaminati4n of wells during the liquid-       	]
<br />     	`.  	Prior to,mater sampling,each weil is purged by aracuating a     	level measurement process,wef[s are measured in the order of
<br /> 			minimum of three wetted well-casing volumes al groundwater.    	"clean"to"dirty"(where such information is available). In
<br /> 			When required, purging t-fill canlinue until either the discharge   	addition, all measurement equipment is cleaned with salut On
<br /> 			water temperature,canductiv t/,ar pN stabilize,a ma)dmum of   	and theraughhy.drised Yv th deion�ed water before use,between
<br /> 			ten wetted-casing volumes of graundvratar have been    		measurements in respective wells,and at the completion of the
<br /> 			recovered, or the well is bailed dry.       				days use.