My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0011870
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
F
>
5491
>
3500 - Local Oversight Program
>
PR0545028
>
ARCHIVED REPORTS_XR0011870
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2019 5:50:11 PM
Creation date
12/6/2019 4:50:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0011870
RECORD_ID
PR0545028
PE
3528
FACILITY_ID
FA0003919
FACILITY_NAME
VAN DE POL ENTERPRISES
STREET_NUMBER
5491
STREET_NAME
F
STREET_TYPE
ST
City
BANTA
Zip
95304
CURRENT_STATUS
02
SITE_LOCATION
5491 F ST
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
87
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> CALIFORNIA LABORATORY SERVICES <br /> i <br /> 02/13/04 15:40 <br /> APEX Envirotech Inc.-Gold River Project: Moore Petroleum CLS Work Order#:CINB0248 <br /> 11244 Pyrites Way Project Number: ERA02.004-QM COC#: 1 and 2 <br /> Gold River,CA 95570 Project Manager: Kasey Jones <br /> Notes and Definitions <br /> D-12 Results in the Gasoline Range are primarily due to overlap from a heavier fuel hydrocarbon product.- <br /> DSL-1 Although sample contains compounds in the retention time range associated with diesel,the chromatogram was not consistent <br /> with the expected chromatographic pattern or"fingerprint". However,the reported concentration is based on diesel. <br /> DSL-3 Although sample contains compounds in the retention time range associated with motor oil,the chromatogram was not consistent <br /> with the expected chromatographic pattern or"fingerprint'. However,the reported,concentration is based on motor oil. <br /> GAS-1 Although sample contains compounds in the retention time range associated with gasoline,the chromatogram was not consistent <br /> with the expected chromatographic pattern or"fingerprint'. However,the reported concentration is based on gasoline. <br /> GC-35 This analyte was analyzed by GCMS-method 8260B. <br /> i <br /> DET Analyte DETECTED <br /> ND Analyte NOT DETECTED at or above the reporting limit <br /> NR Not Reported <br /> dry Sample results reported on a dry weight basis <br /> RPD Relative Percent Difference <br /> E <br /> i <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.