Laserfiche WebLink
I <br /> kn KLEIN FELDER <br /> 1. Down-well equipment (pumps, bailers, etc.) is decontaminated by steam cleaning, or by <br /> scrubbing in a trisodium-phosphate or non-phosphate detergent wash followed by a <br /> distilled water rinse, prior to use in each well. Bailer cord is replaced prior to use in each <br /> well. <br /> 2. The depth to groundwater is measured using a conductivity-based water-level meter. <br /> 3. The volume of water in gallons standing in the well is calculated by subtracting the depth <br /> to groundwater measurement from the depth of the well and multiplying by the <br /> appropriate conversion factor(0.16 for 2-inch wells, and 0.65 for 4-inch wells). <br /> 4. Three to five well volumes of water are purged from each well using a submersible pump, <br /> bladder pump, or Teflon bailer. <br /> 5. Physical parameters (pH, electrical conductivity, and temperature) are monitored for <br /> stability while purging. The physical parameter measurements are recorded on purge- <br /> and-sample logs, along with the time and volume of water purged at each measurement. <br /> 6. Samples are collected with a disposable bailer or bladder pump into appropriately <br /> prepared bottles provided by the analytical laboratory. <br /> 7. Samples for metals analysis are usually filtered in the field at the time of collection. <br /> 1 <br /> 8. Samples are immediately labeled and placed in an iced sample container. At the end of <br /> the day, the samples are delivered to the analytical laboratory under chain-of-custody <br /> control. <br /> l <br /> 1 A-5 Vadose Zone Monitorin <br /> 1. Prior to conducting lysimeter sampling, the pressure-vacuum equipment is checked and <br /> cleaned. A Soil-Moisture hand pump with a pressure-vacuum gage is used to measure <br /> residual and implied pressure-vacuum. Nitrogen gas is used to purge the lysimeter <br /> system for sampling. An air pump is available as a back up. <br /> 2. Approximately one week to one month prior to conducting the sampling, the residual <br /> pressures at the air-line of each lysimeter arc measured ad the vacuums reset to <br /> manufactured recommended value (usually 50 centibars). The measurements and applied <br /> vacuums are noted on a sampling log form. Kleinfelder has found that resetting the <br /> lysimeters vacuums before the sampling yields good sample recovery. <br /> 3. The residual pressures are measured just prior to collecting the sample. The water line is <br /> then opened and nitrogen gas applied to the air line until either fluid or air is discharged <br /> (for dry lysimeters). The sample is contained in a 1 liter unpreserved bottle and the <br /> } <br /> f <br /> 12280.MON/2002R394 Page A-6 <br /> ©2002 Kleinfelder,Inc May 10,2002 <br />