My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0011016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FILBERT
>
110
>
3500 - Local Oversight Program
>
PR0545039
>
ARCHIVED REPORTS_XR0011016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2019 3:42:45 PM
Creation date
12/10/2019 11:36:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0011016
RECORD_ID
PR0545039
PE
3528
FACILITY_ID
FA0010186
FACILITY_NAME
DEL MONTE FOODS PLNT #33 - DISCO WH
STREET_NUMBER
110
Direction
N
STREET_NAME
FILBERT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
15702009
CURRENT_STATUS
02
SITE_LOCATION
110 N FILBERT ST
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
105
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
31604.DSK �. <br /> WP-SFO <br /> B. High-Pressure Sodium: Provide high-pressure sodium ballast with high <br /> power factor for operation at voltage provided. <br /> C. Manufacturer: <br /> I . <br /> 1. High-Pressure Sodium: General Electric, Sylvania, Advance, or <br /> equal. <br /> 2.12 LIGHTING CONTROL <br /> A. Photocells: <br /> 1. Provide automatic ON/OFF switching photo control device, <br /> completely self-contained in die-cast aluminum housing, not affected <br /> by moisture, vibration, or temperature changes; ON at dusk and OFF <br /> at dawn; time delay feature to prevent false switching; and field <br /> adjustable to control operating levels. <br /> 2. Manufacturers: <br /> a. Tork <br /> b. Paragon <br /> C. Or equal. <br /> 2.13 RECEPTACLES <br /> A. Provide UL listed, specification grade receptacles meeting NEMA WD 1 <br /> performance standards and Federal Specification W-C-596 and having a <br /> contact arrangement such that contact is made on two sides of each inserted <br /> blade without detent. Use two-pole, three-wire grounding type receptacles <br /> rated 20 amps, 125 volts, NEMA Configuration 5-20R and with screw type <br /> wire terminals suitable for No. 10 AWG. <br /> 2.14 JUNCTION AND PULL BOXES <br /> A. For hazardous areas, use boxes applicable for the location and hazardous <br /> atmosphere present. <br /> 2.15 GROUNDING <br /> A. . Ground Rods: Provide copper-clad steel ground rods not less than 314-inch <br /> diameter, 10 feet long driven full length into the earth where shown and of <br /> sufficient number to obtain 1 ohm earth resistance as measured by the <br /> three-point method. <br /> B. Ground Conductors: Provide Type THW or THHN/THWN stranded <br /> grounding conductors of the size required by the NEC or shown on the <br /> Drawings whichever is larger. Provide a ground conductor in every <br /> conduit except for conduits carrying circuits 50 volts or less. <br /> C. Ground Connections: <br /> 1. For belowgrade or in-slab connections, provide exothermic-welded <br /> type of connectors as manufactured by Cadweld, Thermoweld, or <br /> equal. <br /> BAE31604.AS.T1 <br /> 16005 5 ELECTRICAL SYSTEM <br />
The URL can be used to link to this page
Your browser does not support the video tag.