Laserfiche WebLink
Not Shownl Does no <br /> REVIEW CHECK LIST Submitted InccmletE Confora,, <br /> E. STCRM SEATER R.EVIE ': <br /> 1. Position of sewer with dimensions to street right-of-way <br /> lines <br /> 2. Lengths of sewer in feet between manholes <br /> 3. -s and size of sewer lines <br /> 4. Design calculations for storm sewer (piping system with <br /> plan showing tributary area, mond etc. ) <br /> 5. Profile of proposed design grade on centeriine oL street <br /> 6. Location of manholes and catch basins, showing fiowline <br /> elevations at manholes (Lat. connected to MH not into <br /> trunk lines) _ <br /> 7. MH spacing (500' max for 24" diameter or smaller, and <br /> 600' max. for > 24" diameter, gutter run to a single SDI <br /> (700' max. ) <br /> 8. Profiles of pioe showing percent slope between manholes <br /> 9. TVoical manhole details <br /> 10. Typical storm drain inlet details (lateral 12" diameter <br /> min. ) <br /> 11. Pumping plant system (including electrical details, pump <br /> house, fence, paved access, unoaved shall be sterilized) <br /> 12. Trash rack (either in last MH before station or an angle <br /> rack in station) <br /> 13. Drainage ponds (volume required and capacity, bottom <br /> elevation, side slopes, fence with 18' double gate, <br /> around water elevation) <br /> 14. Provision for terminal drainage (within one mile of a <br /> terminal drainage facility) <br /> 15. tDutfall structure <br /> lo. Trench detail <br /> 17. Multi-pump system provided <br /> i8. Manufactur?r's specifications and data on pumas and <br /> eguipernnt <br /> 19. Boring reauirement for existing street or road <br /> 20. Coerator's manual for pumps, ecruipment, etc. <br /> REMARKS: <br /> H PS-RCL5 (9/89) <br />