Laserfiche WebLink
CRYSTAL CREAMERY STOCKTON <br /> WKA No. 1628.10 <br /> February 5, 2000 <br /> Page 3 <br /> The average depth-to-groundwater encountered in the wells during the pilot tests was 14.8 feet <br /> bsg. During the first pilot test utilizing VEWI as the vapor extraction well, three influent soil <br /> gas samples VEW14, VEWI-II and VEWI-III were obtained at 30 minutes, 2 hours and 4 hours, <br /> respectively. During the second pilot test using well VEW3 as the vapor extraction well,three <br /> additional influent soil gas samples VEW34,VEW3-II, and VEW3-III were obtained at 30 <br /> minutes, 2 hours and 3-112 hours,respectively. The samples were obtained by connecting I-liter <br /> Tedlar bags to the influent sampling port of the blower. The samples were submitted under chain <br /> of custody to a California-certified laboratory for analysis of Total Petroleum Hydrocarbons. <br /> (TPH) as gasoline using Modified EPA Method 8015,Benzene, Toluene, Ethylbenzene, and <br /> Total Xylenes(BTEX) and Methyl-tent-Butyl ether using EPA Method 8020. <br /> A photoionization detector(PID)was used to measure influent hydrocarbon vapor concentrations <br /> from vapor extraction well VEW1 and VEW3 during the pilot tests. PID readings during the <br /> F_ <, pilot tests ranged from 0.2 molar parts per million(ppm) to 9.5 molar ppm. TPH as gasoline, <br /> MTBE,benzene, and ethylbenzene were not detected in soil gas samples VEWI, VEWI-III, and <br /> VEW3-I through VEW3-III. Results of laboratory analysis revealed TPH as gasoline in soil gas <br /> sample VEW1-11 at a concentration f�6 � molar ppznlTot I Xylenes were detected in sample <br /> VEWI-I at a concentration of0.053 mppm and toluene was detected in all the samples at <br /> concentrations ranging from 0.051 molar ppm to 0.12 molar ppm. <br /> During the test, an average differential vacuum pressure of approximately 40 inches and 36 <br /> inches of H2O were measured at vapor extraction wells VEWI and VEW3,respectively. A <br /> vacuum extraction flow rate of approximately 250 to 280 standard.cubic feet per minute(scfin) <br /> was observed in the extraction well. Vacuum pressure and time were measured at the extraction <br /> and observation wells using Magnehelic pressure gauges. The maximum observed vacuum <br /> pressure drawdowns in VEW2 and VEW3 during the first pilot test were approximately 2.2 and <br /> 1.6-inches of H2O,respectively. The maximum observed vacuum pressure drawdowns in wells <br /> VEWI and VEW2 during the second pilot test were approximately 1.5 and 0.7-inches of HO, <br /> respectively. Graphical representation of vacuum pressure drawdown over time and distance are <br /> included as Appendix A. <br /> WALLACE KUHL <br /> F-ASq®CiATES IM-, <br />