Laserfiche WebLink
M Messrs Trommer and Larson April 29 2009 <br /> March 2010 Draft Five-Year Review Recommendation Page 2 of 3 <br /> Various Sites <br /> 248 E . Park Street, Stockton , CA, Claim Number 1695 : You concurred with the EHD <br /> directive to conduct a dual phase extraction (DPE) pilot test; a work plan for such is due <br /> June 7, 2010 , <br /> 517 E . Fremont Street, Stockton , CA, Claim Number 14349 : You concurred with the <br /> EHD directive to submit a work plan to conduct a soil vapor extraction (SVE ) pilot test. <br /> The results from a recent DPE pilot test were interpreted to show DPE would not be <br /> effective . By letter dated March 9 , 2010 , the EHD approved an SVE/IAS pilot test. The <br /> sparge wells are scheduled for installation in May 2010 . <br /> 15615 Seventh Street, Lathrup, CA, Claim Number 367: You concur with an EHD <br /> approval by letter dated January 8 , 2010 , conducting an oxygen injection pilot test . The <br /> EHD approved collecting groundwater parameters needed to show that low oxygen <br /> concentrations are a limiting factor controlling natural attenuation and that injection of <br /> oxygen may be effective for enhancing natural attenuation . A feasibility study is <br /> pending . <br /> 11530 Eight Mile Road , Stockton, CA, Claim Number 3668 : You concurred with the <br /> EHD directive to conduct ozone sparging pilot test. At this time there is an access <br /> problem for installing the sparge wells at the proposed locations are on a levee and the <br /> Reclamation District has not yet granted access . <br /> 814 Charter Way, Stockton , CA, Claim Number 6793 : You recommend that the EHD <br /> consider site closure; at the time of preparation of this letter the monitoring wells on the <br /> site are being destroyed . As soon as proper disposal of investigation-derived wastes <br /> has been received , a closure letter will be issued . <br /> 5491 F Street, Banta, CA, Claim Number 889 : You recommend that the EHD consider <br /> site closure. A monitoring well installed to further investigate high concentrations of total <br /> petroleum hydrocarbons quantified as motor oil (TPHmo) in a sand unit potentially <br /> contributing to a nearby domestic well has been installed and monitored twice; the <br /> results of the second monitoring event are still pending . The SVE system and ozone <br /> injection system have been offline for several months and rebound testing is in <br /> progress . Assuming favorable results from the groundwater monitoring and rebound <br /> monitoring , the EHD will most likely start the closure process. <br /> 620 W. Charter Way, Stockton , CA, Claim Number 4954: In 2008 and 2009 , you <br /> recommended implementation or enhancement of groundwater remediation in the <br /> deeper zones on the site, generally deeper than 50 feet below surface grade (bsg); to <br /> date remediation of deeper groundwater has not been implemented . This year you <br /> recommend consideration of the site for closure . <br /> I <br /> In response to free product encountered in shallow monitoring well MW15-50 in January <br /> 2009 and high concentrations of total petroleum hydrocarbons quantified as gasoline <br /> 5-Year Reviews for March 2010 Comment Letter 0410.doc <br />