Laserfiche WebLink
IN-TANK ALARMS <br /> Q 3;DIESEL T 2:LEAK ALARM <br /> T 2:HIGH WATER ALARM <br /> TYP:2.0i3.0IN FIBERGLASS T 2:LOW PRODUCT ALARM <br /> 2.01N DIA LEN: 130 FEET <br /> LIQUID SENSOR ALMS <br /> 3.0IN DIA LEN: 0 FEET L 2:FUEL ALARM <br /> L 2:SENSOR OUT ALARM <br /> SHUTDOWN RATE: 3.0 GPH L 2:SHORT ALARM <br /> LOW PRESSURE SHUTOFF:NO L 2:HIGH LIQUID ALARM <br /> LOW PRESSURE 15 PSI L 2:LIQUIII WARNING <br /> EVR ISD SE-UP <br /> TANK: NONE PRESSURE L: NE LEAK <br /> SENSOR: NON-VENTED Q 2:PLLD OPEN ALARM <br /> PRESSURE OFFSET: 5.0PSI PLLD LINE IIISABLF SETUP <br /> _ ISD SITE ALARMS EVk T','1:'E: tlHC:UUM ASSIST <br /> ISD STAGE I WARN VACUUM ASS ST TYPE <br /> Q 1 :87 REGULAR ISD GROSS FRES FAIL HEALY VAC <br /> LINE LEAK LOCKOUT SETUP ISD DEG^RD PRES FAIL <br /> ISD VAPOR LEAK. FAIL NO2 LE H.:L RANGE ISD FUEL GRADE HOSE MAF' <br /> - - - - - IN-TANK ALARMS ISD VP PRES FAIL MAX: 1 . 15 MIN: 0.90 1 2 `� 4 <br /> LOCKOUT SCHEDULE T I :LEAK ALARM FP HHH MHH MHH MHH AA <br /> DAILY ISD VP STATUS FAIL <br /> T 1 :HIUH WATER ALARM <br /> START TIME: DISABLED T 1 :LOW PRODUCT ALARM VAPOR PROCESSOR TYPE 01 201 101 901 3 U 1 <br /> STQP TIME : DISABLED ISD HOSE ALARMS NO VAPOR PROCESSOR 02 202 102 902 3 U 1 <br /> LIQUID SENSOR ALMS ALL:GROSS COLLECT FAIL 03 203 103 903 U U 2 <br /> L 1 :FUEL ALARM ALL:DEGRD COLLECT FAIL 04 204 104 904 U U 2 <br /> L I :SENSOR OUT ALARM ALL:FLOW COLLECT FAIL ANALYSIS T MES 05,205 105 905 3 U 3 <br /> L "1 :SHORT ALARM TIME: 7:30 AM 06 ,206 906 106 3 U 3 <br /> L 1 :HIGH LIQUID ALARM Q 3:DIESEL DELAY P'1INU"ES: 1 07 .207 107 907 U U 4 <br /> LIQUID SENIORSETUP <br /> - - - - - L I :LIQUID WARNING <br /> IN-TANK ALARMS 08 208 108 908 U U 4 <br /> L 1 :87 SUMP SMARTSENSOI; ALARMS T 3-LEAK ALARM ACCEPT HIGH ORVR: <br /> T <br /> DUAL FLT. HIGH VAPOR ALL:SETUP DATA WARNING 3:LOW PRODUCT ALARM ENABLED <br /> LABEL TABLE <br /> CATEGORY : STP SUMP ALL:SENSOR FAULT ALARM -------------------------- <br /> LIQUID SENBOR ALMS ISD HOSE TABLE 1 : UNASSIGNED <br /> ISD SITE ALARMS L 3:FUEL ALARM ID FP FL HL AA RR <br /> L 2:91 SUMP ISD GROSS PRES FAIL L 3:SENSOR OUT ALARM -----------------------__ 2: BLENDS <br /> 3: REGULAh <br /> ISD DEGRD PRES FAIL L 3:SHORT ALARM 01 01 01 02 01 UU 4: MID GRF�DE <br /> DUAL FLT. HIGH VAPOR ISD VAPOR LEAK FAIL L 3:HIGH LIQUID ALARM 02 02 02 02 01 UU 5: PREMIUM <br /> CATEGORY STP SUMP ISD VP PR12S FAIL L 3:LOW L QUID ALARM 03 03 03 02 02 UU 6: GOLD <br /> ISD VP STATUS FAIL L 3:LIQUIII WARNING 04 04 04 02 02 UU 7: BRONZE <br /> L 3:DIESEL SUMP <br /> ISD SENSOR OUT FAIL 05 05 05 02 03 UU 03 UU 8: SILVER DUAL FLT. HIGH VAPOR 06 06 06 02ISD HOSE ALARMS 07 07 07 02 04 UU 9: BLEND2 <br /> CATEGORY : STP SUMP 08 08 08 02 04 UU 10: BLEND4 <br /> ALL:GROSS COLLECT FAIL <br /> ALL:DEGRD COLLECT FAIL <br /> L 4:87 ANNULAR ALL:FLOW COLLECT FAIL ' <br /> DUAL POINT HYDROSTATIC SHARTSENSOR SETUP ISD AIRFLOW METER MAP <br /> CATEGORY : ANNULAR SPACE Q 2:91 PREMIUN _ - _ _ - -- _ - - _ ID SERIAL 14UM LABEL <br /> - ---------- ------- <br /> s --- <br /> 1 :DISP 1­2 1 17470 DISP 1-2 <br /> CATEGORY AIR FLOW METER 2 57700 DISP 3-4 <br /> L 5:91 ANNULAR 3 17468 DISK 5-6 <br /> DUAL POINT HYDROSTATIC s 2:DISP 3--4 4 37993 DISP 7-8 <br /> CATEGORY : ANNULAR SPACE CATEGORY AIR FLOW METER ! PMC SETUP <br /> ' s 3:D I SP 5•-6 PROCESSOR CONTROL LEVEL: <br /> L 6:DIESEL ANNULAR CATEGORY AIR FLOW METER NONE <br /> DUAL POINT HYDROSTATIC. s 4:DISP 7•-8 <br /> CATEGORY : ANNULAR SPACE CATEGORY AIR FLOW METER <br /> s 5:PRESSURE SENS 5-6 <br /> CATEGORY VAPOR PRESSURE <br />