Laserfiche WebLink
1 <br /> App RECEI\!ED <br /> endix VI <br /> MONITORING SYSTEM CERTIFICATION SEP 2 2017 <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7, Health and Safety Code;Chapter 16,Division 3,Title 23,California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or reportm, s �Q Prepared fpr p <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be I A ilBElk system AL HEALTH <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30.days of test date LSV EP t"r <br /> A. Generallnfonnation <br /> Facility Name: PACIFIC SERVICE STATION Bldg.No.: <br /> Site Address: 6131 PACIFIC AVE City: STOCKTON Zip: 95207 <br /> Facility Contact Person: DAV Contact Phone No.: (209)952.4862 <br /> Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: 8131/2017 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicates ecific a ui ment ins ected/serviced: <br /> TanklD: 87 TanklD: 91 <br /> ® In-Tank Gauging Probe. Model: MAG 1 ® In-Tank Gauging Probe. Model: MAG 1 <br /> ® Annular Space or Vault Sensor. Model: 302 ® Annular Space or Vault Sensor. Model: 302 <br /> ® Piping Sump/Trench Sensor(s). Model: 352 ® Piping Sump/Trench Sensor(s). Model: 352 <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ® Electronic Line Leak Detector. Model: PLLD ® Electronic Line Leak Detector. Model: PLLD <br /> ® Tank Overfill/High-Level Sensor. Model: FLAPPER ® Tank Overfill/High-Level Sensor. Model: FLAPPER <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: DIE Tank ID: <br /> ® In-Tank Gauging Probe. Model: MAG 1 ❑ In-Tank Gauging Probe. Model: <br /> ® Annular Space or Vault Sensor. Model: 302 ❑ Annular Space or Vault Sensor. Model: <br /> ® Piping Sump/Trench Sensor(s). Model: 352 ❑ Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ® Electronic Line Leak Detector. Model: PLLD ❑ Electronic Line Leak Detector. Model: <br /> 0 Tank Overfill/High-Level Sensor. Model: FLAPPER El Tank Overfill/High-Level Sensor. Model: <br /> [3Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 3-4 <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ® Dispenser Containment Float(s)and Chain(s). ® Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5-6 Dispenser ID: 7-8 <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ® Dispenser Containment Float(s)and Chain(s). ® Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment <br /> ❑ Dispenser Containment Sensor(s). Model: Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): ®System set-up ®Alarm history report <br /> Technician Name(print): FELIX RAMIREZ Signature: <br /> C <br /> Certification No.: B34976 License No: 5273934-UT 08-1740 OTTL <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0113 <br /> Testing Company Address: 4162 nd STREET GALT CA 95632 Date of Testing/Servicing: 08-31-17 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br />