BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6131
>
2300 - Underground Storage Tank Program
>
PR0231223
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2019 4:25:53 PM
Creation date
12/16/2019 3:24:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231223
PE
2361
FACILITY_ID
FA0002324
FACILITY_NAME
Pacific Service Station
STREET_NUMBER
6131
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
09746418
CURRENT_STATUS
01
SITE_LOCATION
6131 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
152
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Y <br /> FIED PROGRAM CONSOLIDATED FO-jr <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN -(Page I of 2) o <br /> TYPE OF ACTION ® 1.NEW PLAN ❑ 2.CHANGE OF INFORMATION 490-1. <br /> PLAN TYPE ® 1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. SEP 0 490-2 <br /> (Check one item only) [12.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): 8 ZOOS <br /> I. FACILITY INFORMATION ENVIRONMENT HEALTH <br /> FACILITY ID#(Agency Use Only) 1 <br /> BUSINESS NAME(Same as Facility Name or DBA) 3 <br /> Marigold Shell <br /> BUSINESS SITE ADDRESS 6131 Pacific Avenue 103. CITY Stockton 104. <br /> II. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency specified <br /> by the.!gVipment manufacturers'instructions,•orannually,whichever is more frequent_Such work must be performed by_gaalified personnel.[23 CCR§2632,2634,2638,26411 <br /> MONITORING E UIPMENT IS SERVICED ® 1.ANNUALLY [199.OTHERS eci 490-3a. <br /> Q ( P �)� 490-3b. <br /> III. MONITORING LOCATIONS <br /> ❑ ;.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN ❑ 2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED [23 CCR§2632,26141 4904. <br /> [V. TANK MONITORING IS PERFORMED USING THE FOLLOWING METHODS; t(Chtak`11 <br /> ® 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) 490-5. <br /> WITH AUDIBLE AND VISUAL ALARMS.[23 CCR§2632,2634) <br /> SECONDARY CONTAINMENT IS: ❑ a.DRY ® b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 490.6' <br /> PANEL MANUFACTURER: Veeder Root Simplicity 490-7. MODEL#: TLS-350 490-8. <br /> LEAK SENSOR MANUFACTURER: Veeder Root 490-9. MODEL#(S): 302 490-10. <br /> _..• .-......-.....-_ -_._.._._..---...--.----- <br /> ❑ 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).[23 CCR§26431 490-11. <br /> PANEL MANUFACTURER: 490-12. MODEL#: 490-13. <br /> IN-TANK PROBE MANUFACTURER: 490-14. MODEL#(S): 490-15. <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILY/NIGHTLY ❑ c.WEEKLY 490-16. <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): 490-17. <br /> PROGRAMMED TESTS: ❑ a.0.1 h. ❑ b.0.2 h. ❑ c.OTHERS eci ago-18. <br /> .............................................................-..........................................-.........-..-........-......-...._..-_g•I'....._......._...._._.__._..__...._._.._._._..g.p.h. _ .--- _.( P ��:_.. ........_490._19:........._.. <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION(23 CCR§2646.11 ago-2°• <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)[23 CCR§26451 TESTING PERIOD: ❑ a.36 HOURS ❑ b.60 HOURS 422. <br /> .................................._...-__..__.-....._.._...-._.__._.._._._...... 490-22 <br /> ❑ 5.TANK INTEGRITY TESTING PER[23 CCR§2643.11 490-23. <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.BIENNIALLY ❑ c.OTHER(S eci 490- <br /> .......... <br /> 90 z4. <br /> Q -_ P fy): .490•;25,_• <br /> ❑ <br /> 99.OTHER(Specify): 49ago-25:'" <br /> 0-27. <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) that <br /> atak lI1 <br /> ® L CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE&VISUAL ALARMS. 490-28. <br /> [23 CCR SECONDARY CONTAINMENT IS: ® a.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 490-29. <br /> §26361 <br /> PANEL MANUFACTURER:Veeder Root Simplicity 490-30. MODEL#: TLS-350 490-31. <br /> LEAK SENSOR MANUFACTURER: Veeder Root 490-32' N:ODEL#(S): -'E 2 490-33. <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. ® a.YES ❑ b.NO 490-34. <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 490.35. <br /> ❑ 2.MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h. LEAK TESTS AND RESTRICTS OR SHUTS OFF 490-36. <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.[23 CCR§26361 <br /> MLLD MANUFACTURER(S): 490-37. MODEL#(S): 490-38. <br /> ... .................._. - <br /> ® 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS.[23 CCR§26361 490-39- <br /> ELLD MANUFACTURER(S):Veeder Root 490-40. MODEL#(S): PLLD 490-41. <br /> PROGRAMMED IN LINE LEAK TEST: ❑ a.MINIMUM MONTHLY 0.2 g.p.h. ❑ b.MINIMUM ANNUAL 0.1 g.p.h. 49042. <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 49043. <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 490-44. <br /> __....--..._.......___._._.__.._..__-.-_..._......._....__.-_--.__-.....................__._._. __. -.___ <br /> ❑ 4.PIPE INTEGRITY TESTING. 49045. <br /> 46. <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.EVERY 3 YEARS El c.c.OTHER(Specify) 49 . <br /> ❑ 5.VISUAL PIPE MONITORING. 490.48 <br /> FREQUENCY: ❑ a.DAILY ❑ b.WEEKLY ❑ c.MIN.MONTHLY&EACH TIME SYSTEM OPERATED' 49049. <br /> •Allowed for n tonna jt unbu6ed emeS%e9a n-to r fuel Piping only per HSC§25281 <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA. .�._- <br /> [23 CCR§2636(a)(3)1 - - 490-50. <br /> _............._._..-..__..........._... .- <br /> _' <br /> _._--......__.._............._._...__._._.-___...-_.. __..-_ _...._................... _...___....-.........._....--...----._....--...._...-- -.-._............_-._-_._ -._........_..-.........__...__.................... <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM. 490-51 <br /> 52 <br /> El 99.99.OTHER(Specify) . <br /> UPCF UST-D(12/2007)-1/4 www.unidoes.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.