TNIFIED PROGRAM CONSOLIDATED FOR TANK: TA0122305 <br /> �l FAC#: FA0002324 PR#: PR0231223 <br /> UNDERGROUND STORAGE TANKS -T K PAGE 2 18� <br /> VL PIPING CONSTRUCTION(Chock all that apply) Page 5 of 7 <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE ® 1.PRESSURE ❑ 2.SUCTION ❑ 3.GRAVITY 458 ❑ 1.PRESSURE ❑ 2.SUCTION ❑ 3.GRAVITY 459 <br /> CONSTRUCTION ❑1.SINGLE WALL 03.LINED TRENCH ❑99.OTHER 460 ❑ 1.SINGLE WALL ❑ 95.UNKNOWN 462 <br /> ®2.DOUBLE WALL ❑95.UNKNOWN ❑2.DOUBLE WALL ❑99.OTHER <br /> MANUFACTURER 461 MANUFACTURER 463 <br /> ❑ 1.BARE STEEL ❑ 6.FRP COMPATIBLE w/100%METHANOL ❑ 1.BARE STEEL ❑ 6.FRP COMPATIBLE w/10W.METHANOL <br /> ❑ 2.STAINLESS STEEL ❑ 7.GALVANIZED STEEL ❑2.STAINLESS STEEL ❑ 7.GALVANIZED STEEL <br /> ❑ PLASTIC COMPATIBLE W/CONTENTS ❑ 95.UNKNOWN ❑ PLASTIC COMPATIBLE W/CONTENTS ❑95.UNKNOWN <br /> M 4.FIBERGLASS ❑ 8.FLEXIBLE(HDPE) ❑ 99.OTHER ❑4.FIBERGLASS ❑8.FLEXIBLE(HDPE) ❑99.OTHER <br /> ❑ 5.STEEL W/COATING ❑ 9.CATHODIC PROTECTION 464 ❑ 5.STEEL W/COATING ❑9.CATHODIC PROTECTION 466 <br /> VII.PIPING LEAK DETECTION(Chock all that apply)(A description of the monitoring program shall be submitted to the local agency.) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> ❑ 1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF ❑ 1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF <br /> FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND <br /> VISUAL ALARMS. VISUAL ALARMS. <br /> ❑ 2.MONTHLY 0.2 GPH TEST ❑2.MONTHLY 0.2 GPH TEST ❑ 3.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 3.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑4.DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> ❑ 5.DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIEAL PIPING ❑ 5.DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> INTEGRITY TEST(0.1 GPH) ❑6.TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): <br /> ❑ 7.SELF MONITORING <br /> ❑ 7.SELF MONITORING <br /> GRAVITY FLOW <br /> ❑ 9.BIENNIAL INTEGRITY TEST(0.1)GPH <br /> GRAVrIY FLOW(Check all that apply): <br /> ❑ 8.DAILY VISUAL MONITORING <br /> ❑ 9.BIENNIAL INTEGRITY TEST(0.1)GPH <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(Chock one) ALARMS AND(Check one) <br /> ❑a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ® b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM Elb.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION <br /> DISCONNECTION <br /> ❑c. NO AUTO PUMP SHUT OFF ❑c. NO AUTO PUMP SHUT OFF <br /> ® 11.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR ❑ 11 AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> / -X12.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br /> ❑ 13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that appy) EMERGENCY GENERATORS ONLY(Chock all that apply) <br /> ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF• ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF <br /> AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br /> ❑ 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW ❑ 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW <br /> SHUT OFF OR RESTRICTION SHUT OFF OR RESTRICTION <br /> $t 6.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 16.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 17.DAILY VISUAL CHECK ❑ 17.DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ® I.FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑4.DAILY VISUAL CHECK <br /> DATE INSTALLED <br /> 468 ❑ 2.CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 5.TRENCH LINER/MONITORING <br /> ❑ 3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR ❑6.NONE <br /> DISPENSER+AUDIBLE AND VISUAL ALARMS 469 <br /> IX.OWNERIOPERATOR SIGNATURE <br /> 1 ccrtifv that the information provided heroin is trot and accurate to the best of my knowledge. <br /> RE OF ONkINER/ODERATOR v DA I E O _ _ J 470 <br /> NAME OF O R/OPERATOR(print) 1 �� `� �� TITLE OF OWNER/OPERATOR / <br /> 'BIMCE /I 471 s/ 472 <br /> Permit Number(For local use only) 473 Permit Approved(For local Vc onh) ala Permit Expiration Datc(For local use only 475 <br /> PT0006656 EE0000 6 1/1/1993 12:00:OOAM <br /> UPCF(12/99 revised) <br />