Laserfiche WebLink
07111/96 <br /> QUALITY CONTROL REPORT DHS Certification #1400 <br /> Volatile Analyses <br /> Client: DEL-TECH Date Received: 07/03/96 <br /> 10624 Olive Ave Date Started: : 07/08/99 <br /> Oakdale, CA 95361 Date Complete: 07/10/96 <br /> ATTN., Don Light <br /> Lab Report#: H6070302 Lab Sample al`s PHS070544-660 <br /> Lineari Check: <br /> BTEX Benzene 0.9892 TPH Gasoline O.999e <br /> Toluene Q9983 TPH Diesel N/A <br /> Ethyl Benzene 0.9969 Motor Oil N/A <br /> Xylenes M9998 TRPH (418.1) N/A <br /> error <br /> " EE QZ;Z; <br /> Std tablilty MTBE Benzene Toluene Eth Benz Xylenes <br /> BTEX 110 96 101 102 94 <br /> TPH Gasoline 99 TPH Diesel N/A <br /> TRPH (418.1) NIA TPH Motor Oil N/A <br /> Matrix Spike Recoveries MS MSD RPD <br /> MTBE 1020 94.0 8.2 <br /> BTEX Benzene 99.0 96.0 &1 <br /> Toluene 100.0 101.0 1.0 <br /> Ethyl Benzene 105.0 102.0 29 <br /> Xylenes 107.0 110.0 2,e <br /> TPH Gasoline 91.0 88.0 3.4 <br /> TPH Diesel NAI N/A <br /> TRPH 4191 NIA <br /> Method Blank_____j MTBE Benzene Toluene Eth Benz Xylenes <br /> BTEX c5 mg/Ka mg/K5.3 u L c.3 ug/L C.3 ug/L_ <.3 ug/L <br /> TPH Gasoline <50 u L TPH Diesel/MO N/A TRPH(418.1) N/A <br /> Lab Control Sample% Recovery EPA Performance Acceptance Range <br /> STEX Benzene 101 37.0 - 131.0 <br /> Toluene 108 47.0 - 150.0 <br /> Ethyl Benz 101 36.9 - 1620 <br /> Xylenes 126 42.7 - 137.9 <br /> TPH Gasoline 102 33.0 - 130.1 <br /> TPH Diesel N/A 45.1 - 135.2 <br /> TRPH (418.1) N/A N/A <br /> Gloria Poling, Lab Director <br />